ANALYSIS OF COOLING SYSTEM EFFICIENCY

نویسندگان

چکیده

Introduction: The main task of cooling systems in the machine room a data center is to maintain optimal air parameters at inlet IT equipment accordance with applicable regulatory documents. If value temperature exceeds value, then so-called hot spots occur — operation such places can lead its overheating and failure. reason for occurrence violation circulation between cold aisles. Purpose study: We aimed analyze influence different methods aisle isolation on efficiency cooling. Methods: performed modeling capacity values STAR-CCM+ program. Result: As result studying conditions center, we found most rational way isolating top horizontal containments vertical blind panels free rack space.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Solar Absorption Cooling System Considering Hourly Analysis

Thermal modelling and optimal design of a solar absorption cooling system are presented, and hourly analysis is performed over the period of a year. Three design parameters are considered, then the Real Parameter Genetic Algorithm (RPGA) is applied to obtain the minimum total annual cost. The optimization results show that the solar cooling optimum configuration needs 1630 square meter collecto...

متن کامل

Technical-economic analysis of the combined system power generation, production of fresh water and cooling production

In gas power plants, a lot of energy is lost in the form of heat more than the electricity produced. In the present research, techno-economic evaluation of combined power, desalination and cooling systems running by the exhaust flue gases of a gas turbine in Iran is performed. In addition to using power generated by the gas turbine, attempts were made to use Organic Rankine Cycle to recover the...

متن کامل

Thermo-Economic Analysis of Applying Cooling System Using Fog on GE-F5 Gas Turbines (Case Study)

Presently, nearly 26,000 MW gas power plant and nearly 16,000 MW of combined cycle has been installed in the country. But their power output in summer reduces to a minimum, where most demand is required, compared to the winter season. The main reason for that is gas turbine dependence on the ambient air temperature. Since most of our country has warm and dry climates, cooling down the input air...

متن کامل

Energy Efficiency Evaluation and Economic Feasibility Analysis of a Geothermal Heating and Cooling System with a Vapor-Compression Chiller System

Increasing attention has been given to energy utilization in Turkey. In this report, we present an energy efficiency evaluation and economic feasibility analysis of a geothermal heating and cooling system (GSHP) and a mechanical compression water chiller system (ACHP) to improve the energy utilization efficiency and reduce the primary energy demand for industrial use. Analyses of a mechanical w...

متن کامل

assessment of the efficiency of s.p.g.c refineries using network dea

data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Architecture and engineering

سال: 2022

ISSN: ['2500-0055']

DOI: https://doi.org/10.23968/2500-0055-2022-7-4-49-59