Analysis of coal tar pitches by liquid ionization MS.
نویسندگان
چکیده
منابع مشابه
Coal tars and coal tar pitches.
Numerous studies, mostly case reports, have found that occupational exposure to coal tars or coal-tar pitches (coal-tar distillates) is associated with skin cancer, including scrotal cancer; workers in these studies have included patent-fuel (coal-briquette) workers, pitch loaders, workers in electrical trades, and optical-lens polishers (IARC 1985, 1987). A 1946 study in the United Kingdom fou...
متن کاملCoal Tar Analysis by Lc/ms
The production of liquids from coal gives rise to complex intermediates which require detailed analysis to understand the processes occurring and to make effective use of the products. Analysis has hitherto been based on structural parameters from NMR methods (1) to give the average characteristics of the sample, supplemented by molecular information from GC and GC/MS. The gas chromatographic a...
متن کاملProduction of Mesophase Pitch from Coal Tar and Petroleum Pitches using Supercritical Fluid Extraction
Supercritical fluid extraction (SFE) is currently being investigated as a possible technique in the production of high quality mesophase pitch from coal tar and petroleum pitches. Mesophase pitch is used to make high technology products, such as carbon fibre. The conventional production of mesophase pitch initially involves the removal of low molecular weight species from coal tar and petroleum...
متن کاملActivated carbons prepared from thermally and chemically treated petroleum and coal tar pitches
Petroleum and coal tar pitches have been treated thermally at 4008C and 4708C, extracted with toluene and subsequently activated with CO at 9008C. With one exception, the development of the micropore widths and volumes in the resulting 2 carbons follows the trend observed for carbons based essentially on precursors of vegetable origin. On the other hand, petroleum pitch treated at 4008C leads t...
متن کاملDirect analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS).
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW < or = 25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1988
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.37.17