Analysis of airborne pollen time series originating from Hirst-type volumetric samplers—comparison between mobile sampling head oriented toward wind direction and fixed sampling head with two-layered inlet

نویسندگان

چکیده

Abstract In this study, we have compared time series of pollen concentration originating from two Hirst-type volumetric samplers that were equipped with different sampling heads. To collect airborne pollen, used classic sampler mobile head including wind vane and adapted fixed having two-layered inlet, like in Sigma-2 passive sampler. The devices placed at the roof level, on top building Faculty Sciences located Novi Sad, Serbia. was performed February until October 2019. Along data, meteorological conditions recorded an automated weather station measuring solar radiation, air temperature, relative humidity, speed precipitation. Time daily concentrations expressed high correlations, although there large differences hourly basis. Absolute difference between values showed very weak correlation relevant parameters: precipitation, turbulent kinetic energy, leading to conclusion both heads not affected by conditions. Counting grains whole sample just 10% area, which is minimum requirement, done for six days season proved error introduced subsampling during analysis main reason series. conclude, replacing inlet does notably affect quantity method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a contrastive analysis of concord and head parameter in english and azerbaijani

این پایان نامه به بررسی و مقایسه دو موضوع مطابقه میان فعل و فاعل (از نظر شخص و مشار) و هسته عبارت در دو زبان انگلیسی و آذربایجانی می پردازد. اول رابطه دستوری مطابقه مورد بررسی قرار می گیرد. مطابقه به این معناست که فعل مفرد به همراه فاعل مفرد و فعل جمع به همراه فاعل جمع می آید. در انگلیسی تمام افعال، بجز فعل بودن (to be) از نظر شمار با فاعلشان فقط در سوم شخص مفرد و در زمان حال مطابقت نشان میدهند...

15 صفحه اول

Design and Operation of a Pressure-Controlled Inlet for Airborne Sampling with an Aerodynamic Aerosol Lens

Roya Bahreini,1,2 Edward J. Dunlea,1 Brendan M. Matthew,1,2,3 Craig Simons,1,2 Kenneth S. Docherty,1 Peter F. DeCarlo,1,4 Jose L. Jimenez,1,5 Charles A. Brock,2 and Ann M. Middlebrook2 1Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, Colorado, USA 2Earth System Research Laboratory, National Oceanic and Atmospheric Administration, Boulder, Colorado,...

متن کامل

Airborne Mycotoxin Sampling and Screening Analysis

The indoor mycotoxins inhalation exposure of patients (n=25) was studied using a highvolume air sampler (60 cfm x 24 h) with a micropore-paper filter (8x11 inches). The filters were evaluated for cytotoxicity caused by mycotoxins using the MTT-cell culture bioassay and by culture identification. A subset of samples was analyzed with an enzyme-immuno assay for occurrence of macrocyclic trichothe...

متن کامل

Solitary Head and Neck Cysticercosis: A Series of Rare Cases

Introduction: Cysticercosis is a disease which is caused by the infestation of the larvae Taenia solium, with humans acting as an intermediate host instead of a definitive host. Head and neck involvement including maxillofacial and oral involvement of cysticercosis is quite rare.  Case Report: We report a series of rare cases of cysticercosis of the head and neck region encountered in a tertia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Aerobiologia

سال: 2021

ISSN: ['0393-5965', '1573-3025']

DOI: https://doi.org/10.1007/s10453-021-09695-7