Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
نویسندگان
چکیده
منابع مشابه
Vibration Control of Structures with Initially Accelerated Passive Tuned Mass Dampers under Near-Fault Earthquake Excitation
This article deals with the applicability of passive tuned mass damper (PTMD) for reducing the dynamic responses of structures under near-fault earthquake excitations. Three types of pulse-like time functions are employed to simulate the near-fault ground motion. The vibration control effectiveness of PTMDs is extensively investigated through the comparisons of response spectrum and response ti...
متن کاملSemiactive Tuned Mass Dampers
Studies have already demonstrated the successful use of linear semiactive damping devices, such as variable orifice (VO) dampers, for semiactive TMD systems. More recently, nonlinear semiactive damping devices, such as magnetorheological (MR) dampers, have also been shown to be effective for semiactive control of TMDs. Though semiactive dampers differ widely, with responses ranging from linear ...
متن کاملTHE CAPABILITY OF OPTIMAL SINGLE AND MULTIPLE TUNED MASS DAMPERS UNDER MULTIPLE EARTHQUAKES
The main focus of this research has been to investigate the effectiveness of optimal single and multiple Tuned Mass Dampers (TMDs) under different ground motions as well as to develop a procedure for designing TMD and MTMDs to be effective under multiple records. To determine the parameters of TMD and MTMDs under multiple records various scenarios have been suggested and their efficiency has be...
متن کاملTuned Mass Dampers for Earthquake Vibrations of High-rise Buildings using Bee Colony Optimization Technique
This paper investigates the application of Artificial Bee Colony (ABC) method for the optimization of Tuned Mass Dampers (TMDs) employed for high-rise structures including Soil Structure Interaction (SSI). The model is a 40-story building, and Newmark method is utilized for the structure response to Bam earthquake data. The objective is to decrease both maximum displacement and accelerati...
متن کاملAnalysis of Tall Buildings with Bundled Tube System Subjected to Wind and Earthquake loads
At present, the tubular structural systems are mainly used in tall buildings to withstand earthquake loads. Although it is possible to analyse the structure by finite element methods using standard three dimensional programs, the system is generally time-consuming and expensive in the primary design work. In this paper, for the analysis of Framed-Tube systems, a simple method was studied and de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Shock and Vibration
سال: 2019
ISSN: 1070-9622,1875-9203
DOI: 10.1155/2019/7091819