Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image based magnetic field background correction for aortic and pulmonary artery flow measurement using phase contrast

Methods A large gel phantom was used to assess phase offset in through-plane phase contrast images in x (left to right), y (anterior to posterior) and z directions at the isocenter and in positions ±40 mm and ±80 mm away from the isocenter. Repeated measures were averaged and fit to linear regressions. Phase correction was validated in human study for the assessment of aorta and pulmonary arter...

متن کامل

Image based background magnetic field correction for aortic and pulmonary artery flow measurement using phase contrast

Methods Twelve volunteers underwent breath-hold through-plane phase contrast (PC) imaging of cross sectional view of the ascending aorta and PA. PC imaging was immediately repeated on a static fluid-filled phantom. Phase images were analyzed using QFlow (Medis, Leiden, Netherlands.). Phase shift was also analyzed in static background and in surrounding tissues including chest wall fat and muscl...

متن کامل

Background phase correction using k-space filters in phase contrast velocity encoded MRI

Figure 5: In-vivo background phase correction. (a) Magnitude image, (b) the original phase image, with the dashed blue line defining the area and (c) the red contour of stationary tissue for polynomial surface subtraction, (d) is ground truth, (e) 5th order polynomial subtraction, and (f) k-space filtering with a 64×64 pixel Gaussian kernel. Figure 1: phantom with steady-state flow. Red lines s...

متن کامل

Effects from RF spoiling disequilibrium in the background offsets of phase-contrast velocity imaging

Background Phase-contrast imaging normally uses gradient-echoes with RF spoiling and phase-encode rewinding with a fixed dephasing by gradient “spoiler” pulses in each TR (time between RF pulses) studied in detail (1) where effective artifact suppression in magnitude images required >≈ 8PI dephasing over the slice thickness, with >≈ 2PI dephasing over an FE pixel. However, the effectiveness of ...

متن کامل

Analysis and Correction of the Effect of Spatial Gradient Field Distortions on Velocity Measurements with Phase Contrast MRI

An analysis of the effect of spatially inhomogeneous gradient fields on quantitative phase contrast MRI measurements is presented. A local error in the gradient strength leads to incorrect velocity encoding. Here the error in the measured velocities is compared to a theoretical model of gradient field imperfection. Depending on the spatial location of the region of interest for velocity measure...

متن کامل