Analyses on an electronic voltage transformer's failure by its resonance with very fast transient overvoltage and suppression
نویسندگان
چکیده
Abstract As voltage measuring devices are widely used in the high power system with a primary‐secondary‐fusion structure, electronic transformers directly connected to primary conductor and would face much more serious electromagnetic environments than general secondary equipment. result, they still experience failures even when protection measures adopted suppress overvoltages' amplitudes. To address this issue, an innovative method is proposed after analyses conducted on resonance between transformer overvoltage. Within method, air‐cored coil installed artificially shift its natural frequency dodge high‐frequency dominant component of transient overvoltage, avoiding aforementioned suppressing In addition, simulations laboratory tests prove method's validity.
منابع مشابه
Ferroresonance Suppression in Voltage Transformers
Ferroresonance is a special case of disturbance that involves high levels of overvoltage and overcurrents distortion. This phenomenon can severely affect voltage transformers and its consequences can be catastrophic. This paper analyses different practical solutions against ferroresonance phenomenon in voltage transformers, highlighting the current development of ferroresonance detection techni...
متن کاملElectronic Voltage and Current Transformers Testing Device
A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation s...
متن کاملElectronic compensation of inductive voltage dividers and standard voltage transformers
A new compensating system is proposed to reduce the ratio error and the phase error of inductive voltage dividers and standard voltage transformers, operating at no load. An electronic amplifier reduces the input current, which is the main cause of error in low-frequency applications, while at the same time the input impedance is greatly increased.
متن کاملSF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress
In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...
متن کاملTransient Voltage Surge Suppression- Tvss Designs
Transient voltage surge suppression is a very necessary ingredient for most electronic and computer devices that are exposed to telecommunications or power lines. Nevertheless, the effective application, design, and manufacturing still tends to be more art than science. The authors conducted over 100 tests of various commercial devices. The results were astounding. As a part of the project, des...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: High voltage
سال: 2023
ISSN: ['2397-7264', '2096-9813']
DOI: https://doi.org/10.1049/hve2.12370