Analisa Pengaturan Kelembapan Air Handling Unit Area Produksi Vaksin Sinovac PT. Biofarma

نویسندگان

چکیده

Air Handling Unit is an environmental conditioning unit by controlling temperature, humidity, air movement direction, quality, and particles in the air. AHU has a very important role for pharmaceutical industry, system there are critical parameters that can affect product quality such as temperature so both values ​​must always be maintained accordance with standards set points determined CPOB (Good Manufacturing Practices of Medicines). ) under supervision BPOM. sets standard 20oC humidity 55% class B class. Humidity control analysis carried out comparing actual point then plotting on psychromteric chart new obtained reaches point, from calculation results The mass flow rate water needed to reach cooling coil 1.75889 kg/s, amount energy 29.82233173 kJ/s, after adjusting until RH done heating through sensible heating, result required 1.758925 raise 17.2oC 18.98319 kJ/s. s.s d keep value Good (CPOB)

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cooling output optimization of an air handling unit

A data-driven optimization approach for minimization of the cooling output of an air handling unit (AHU) is presented. The models used in this research are built with data mining algorithms. The performance of dynamic models build by four different data mining algorithms is studied. A model extracted by a neural network is selected for identifying the functional mapping between specific outputs...

متن کامل

Implementation of the Laboratory Air Handling Unit Systems (LAHU)

The LAHU system has been designed, installed, and commissioned in a large university research building. This paper provides detailed information about the demonstration project, including the specific LAHU system mechanical design, optimal airflow control schedules, and measured LAHU energy and indoor air quality (IAQ) performance. The measured energy and IAQ performance are also compared with ...

متن کامل

Achieving 'excellent' indoor air quality in commercial offices equipped with air-handling unit--respirable suspended particulate.

UNLABELLED A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficien...

متن کامل

Robust Sliding Mode Control of Air Handling Unit for Energy Efficiency Enhancement

In order to achieve feasible and copacetic low energy consuming building, a robust and efficient air conditioning system is necessary. Since heating ventilation and air conditioning systems are nonlinear and temperature and humidity are coupled, application of conventional control is inappropriate. A multi-input multi-output nonlinear model is presented. The temperature and humidity of thermal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jurnal Teknik Energi

سال: 2023

ISSN: ['2089-2527']