An unusual plank-shaped nematogen with a graphene nanoribbon core
نویسندگان
چکیده
منابع مشابه
Z-shaped graphene nanoribbon quantum dot device
Stimulated by recent advances in isolating graphene, the authors discovered that a quantum dot can be trapped in a Z-shaped graphene nanoribbon junction. The topological structure of the junction can completely confine electronic states. By varying the junction length, the authors can alter the spatial confinement and the number of discrete levels within the junction. In addition, a quantum dot...
متن کاملBallistic rectification in a Z-shaped graphene nanoribbon junction
Z. F. Wang, Qunxiang Li, Q. W. Shi, Xiaoping Wang, J. G. Hou, Huaixiu Zheng, and Jie Chen Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026, People’s Republic of China Department of Electrical and Computer Engineering, University of Alberta, AB T6 G 2V4, Canada National Institute of Nanotechnology, Department of Ele...
متن کاملJosephson Current For a Graphene Nanoribbon Using a Lattice Model
A tight binding approach based on the Bogoliubov-de Gennes approach has been used to calculate the DC Josephson current for a lattice model for S-GNR-S junctions , for short junctions with respect to superconducting coherence length. We calculate the phase, length, width and chemical potential dependence at the Josephson junction and discuss the similarities and differences with regard to the t...
متن کاملA graphene nanoribbon memory cell.
S D C1 C2 Over the past few years there has been a surge of interest in graphene, a recently isolated [ 1 ] one-atom-thick layer of carbon atoms arranged in a honeycomb lattice. From the application point of view this interest has mainly been driven by the high carrier mobility of graphene [ 2–4 ] which enables fabrication of fi eld-effect transistors (FETs) with much smaller channel resistance...
متن کاملAn unusual shaped IUS.
A 45-year-old nulliparous woman attended for removal and replacement of a levonorgestrel-releasing intrauterine system (IUS) for continued management of dysmenorrhoea. I had placed the IUS some 6 years previously under a cervical block, needing to dilate the tight cervical canal for insertion. The patient’s periods had been well controlled. The IUS was easily removed but, as pictured, the arms ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Materials Chemistry C
سال: 2019
ISSN: 2050-7526,2050-7534
DOI: 10.1039/c9tc03704g