An Ultrasonic Caliper Device for Measuring Acoustic Nonlinearity

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methods for measuring acoustic power of an ultrasonic neurosurgical device.

Measurement of the acoustic power in high-energy ultrasonic devices is complex due to occurrence of the strong cavitation in front of the sonotrode tip. In our research we used three methods for characterization of our new ultrasonic probe for neuroendoscopic procedures. The first method is based on the electromechanical characterization of the device measuring the displacement of the sonotrode...

متن کامل

An Ultrasonic Tree Trunk Diameter Caliper

A unique sensing system is described using an ultrasonic transducer for measuring tree trunk diameters in the orchard. Trunk diameters were calculated from the time it took sound waves to travel from the transducer to the trunk and back to the sensor. The device was calibrated with objects ranging in diameter from 1.6 (0.63 inch) to 19.0 cm (7.5 inches). The distance between the transducer and ...

متن کامل

Ultrasonic device for measuring periodontal attachment levels

Periodontal disease is manifested clinically by a degradation of the ligament that attaches the tooth to the bone. The most widely used diagnostic tool for assessment of periodontal diseases, measurement of periodontal attachment loss with a manual probe, may overestimate attachment loss by as much as 2 mm in untreated sites, while underestimating attachment loss by an even greater margin follo...

متن کامل

Acoustic Emission and Echo Signal Compensation Techniques Applied to an Ultrasonic Logging-While-Drilling Caliper

A logging-while-drilling (LWD) caliper is a tool used for the real-time measurement of a borehole diameter in oil drilling engineering. This study introduces the mechanical structure and working principle of a new LWD caliper based on ultrasonic distance measurement (UDM). The detection range is a major performance index of a UDM system. This index is determined by the blind zone length and rem...

متن کامل

Measuring acoustic nonlinearity parameter using collinear wave mixing

Related Articles Quantitative evaluation of hidden defects in cast iron components using ultrasound activated lock-in vibrothermography Rev. Sci. Instrum. 83, 094902 (2012) Quantitative trap and long range transportation of micro-particles by using phase controllable acoustic wave J. Appl. Phys. 112, 054908 (2012) Nonlinear nonclassical acoustic method for detecting the location of cracks J. Ap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics Procedia

سال: 2016

ISSN: 1875-3892

DOI: 10.1016/j.phpro.2016.12.015