An Optical Fiber-Based Gating Device for Prospective Mouse Cardiac MRI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective synchronization of small animal cardiac MRI: a quantitative comparison of an optical device, pressure sensor and ECG

Introduction Prospective synchronization on living organisms of MRI acquisitions to reduce the motion artifacts involves the monitoring of both respiratory and heart motions in the thorax and abdominal region. The signal conventionally used to measure cardiac cycle is the electrocardiograph (ECG) signal. Because of the weak amplitude of the ECG signal recorded on small animals, to obtain an unc...

متن کامل

Mouse cardiac MRI: comparison of prospective synchronization using optical and ECG signals with a retrospective technique

Introduction Prospective synchronization on living organisms of MRI acquisitions to reduce the motion artifacts involves the monitoring of both respiratory and heart motions in the thorax and abdominal region. The signal conventionally used to measure cardiac cycle is the electrocardiograph (ECG) signal. Respiratory motion can be derived from low frequency modulation of ECG signal [1]. Because ...

متن کامل

All-optical multichannel 2R regeneration in a fiber-based device.

We propose the design of an all-optical 2R regenerator capable of handling multiple wavelength-division-multiplexed channels simultaneously. It extends the known concept of off-center filtering of self-phase-modulation-broadened signal spectra. The novel feature of the proposed device is a dispersion map that strongly suppresses interchannel impairments. The map employs several sections of nonl...

متن کامل

Utility of Cardiac Gating for Pulmonary Perfusion MRI

INTRODUCTION Cardiac motion is a common source of artifacts when imaging the chest with methods such as pulmonary perfusion MRI and pulmonary MR angiography (MRA). To minimize these artifacts, the MR sequence is often ECG-gated such that data are only acquired during a portion of the cardiac cycle when the heart is relatively quiescent; typically during diastole. However, this reduces scan effi...

متن کامل

Improved ECG based gating in ultra high field cardiac MRI using an independent component analysis approach

Background Cardiac gating in ultra high field (UHF) MRI is a challenging task due to the magnetohydrodynamic (MHD) effect [1]. The MHD effect is particularly severe at such field strengths and severely distorts the electrocardiogram (ECG). State-of-the-art ECG based gating methods which use the vectorcardiogram (VCG) [2] are thus prone to errors [1]. This work presents an approach which separat...

متن کامل