An off-line two-dimensional analytical procedure for determination of polycyclic aromatic hydrocarbons in smoke aerosol
نویسندگان
چکیده
منابع مشابه
Off-line solid-phase extraction procedure for the determination of polycyclic aromatic hydrocarbons from aqueous matrices
An off-line solid-phase extraction procedure followed by high-performance liquid chromatography with ultraviolet detection for the determination of 16 priority polycyclic aromatic hydrocarbon pollutants in aqueous matrices was described. Diverse aspects determining extraction efficiency such as packing type (disk or cartridge), elution solvents and addition of organic modifiers to the sample we...
متن کاملDetermination of Polycyclic Aromatic Hydrocarbons in Ambient Urban Air
Polycyclic aromatic hydrocarbons (PAHS) have been determined in the atmosphere of Isfahan, Iran. Airborne particulate matter was sampled using a high-volume air sampler at roof-top level (~6m). Extraction of PAHS from airborne particulate matter has been performed using SFE system and the relationship between the extraction temperature and the recovery of PAHS</su...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملSample preparation procedure for the determination of polycyclic aromatic hydrocarbons in petroleum vacuum residue and bitumen
This paper describes a novel method of sample preparation for the determination of trace concentrations of polycyclic aromatic hydrocarbons (PAHs) in high-boiling petroleum products. Limits of quantitation of the investigated PAHs in materials of this type range from tens of nanograms per kilogram to <20 μg/kg. The studies revealed that in order to separate most of interferences from the analyt...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of High Resolution Chromatography
سال: 1987
ISSN: 0935-6304,1521-4168
DOI: 10.1002/jhrc.1240100605