Two-channel data logger for quantitative EEG recording while driving
-A hardware and software design and development is described for a two-channel portable recording device specifically to collect the electroencephalogram (EEG). The application intended for this device was collection of EEG data from drivers, while driving under controlled conditions on closed roads or circuits. The monitoring of driver reactions may lead to a better understanding of driving ab...
متن کاملAn MS-DOS Filesystem for UNIX
We have written DosFs, a new file system for UNIX that uses MS-DOS data structures for permanent storage. DosFs can be used anywhere a traditional UNIX file system can be used, and it can mount disks written by MS-DOS as regular UNIX partitions. DosFs can be used as the root partition, and exported by an NFS server. Our motivation for this work was efficient disk space utilization; DosFs provid...
متن کاملA miniaturized threshold-triggered acceleration data-logger for recording burst movements of aquatic animals.
Although animal-borne accelerometers are effective tools for quantifying the kinematics of animal behaviors, quantifying the burst movements of small and agile aquatic animals remains challenging. To capture the details of burst movements, accelerometers need to sample at a very high frequency, which will inevitably shorten the recording duration or increase the device size. To overcome this pr...
متن کاملAn advanced physiological data logger for medical imaging applications
The interest of physiological data sensing and recording using wireless body sensor network has increased in recent years due to the advancement of miniature and portable electronic devices. In this study, the design of a portable and rechargeable data logger with high data rate multiple wireless connectivity (Bluetooth and 2.4-GHz radio frequency) is discussed. The data are logged in micro sec...
متن کاملMRI compatible hemodynamic recording system
Background During cardiovascular interventions it is critical to have high-fidelity hemodynamic recordings of physiologic signals for patient safety and procedure guidance. MRI compatible monitoring systems are low-fidelity and not suitable for cardiovascular interventions. We present an MRI compatible hemodynamic recording system designed for MRI guided cardiovascular interventions. It is capa...