An Investigation of Adaptive Pen Pressure Discretization Method Based on Personal Pen Pressure Use Profile

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Adaptive Pen Pressure Discretization Method Based on Personal Pen Pressure Use Profile

SUMMARY Continuous pen pressure can be used to operate multi-state widgets such as menus in pen based user interfaces. The number of levels into which the pen pressure space is divided determines the number of states in the multi-state widgets. To increase the optimal number of divisions of the pen pressure space and achieve greater pen pressure usabil-ity, we propose a new discretization metho...

متن کامل

The Adaptive Hybrid Cursor: A Pressure-Based Target Selection Technique for Pen-Based User Interfaces

We present the Adaptive Hybrid Cursor, a novel target acquisition technique for pen-based interfaces. To assist a user in a target selection task, this technique automatically adapts the size of the cursor and/or its contexts (the target size and the selection background) based on pen pressure input. We systematically evaluated the new technique with various 2D target acquisition tasks. The exp...

متن کامل

An insight into the freedom of using a pen: Pen-based system and pen-and-paper

In recent years the studies of freehand sketch began to peek into cognitive study area from the design media aspect. The development of pen-based system attempted to use pen as an input device, allowing sketches to be freely drawn in computers environment. The importance of the freehand sketch is in its ability to freely represent various drawing projections using ambiguous sketches. However, a...

متن کامل

Semantic Pen - A Personal Information Management System for Pen Based Devices

The Onset of Semantic Web technology have promised a new vision of Personal Information Management (PIM). With the advent of Pen-based computing, PIM faces new challenges: usability and flexibility are important constraints in the pen based environment. We present our system of Semantic Pen an augmented pen based PIM system that merges the efficiency of semantic web with the usability of pen ba...

متن کامل

Noninvasive measurement of rat intraocular pressure with the Tono-Pen.

PURPOSE The purpose of this study was to evaluate the Tono-Pen 2 tonometer for measuring intraocular pressure (IOP) in the living rat eye. METHODS One eye from each of 20 adult, anesthetized brown Norway rats (group 1) was cannulated and simultaneously connected to a syringe and a pressure transducer with a chart recorder. We increased IOP from 15 to 45 mmHg in 5-mmHg increments and obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEICE Transactions on Information and Systems

سال: 2010

ISSN: 0916-8532,1745-1361

DOI: 10.1587/transinf.e93.d.1205