An intermediate experiment with a lossy transmission line
نویسندگان
چکیده
منابع مشابه
A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon
To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common c...
متن کاملLossy Transmission Line Response via Numerical Laplace Transform Inversion
An efficient transient analysis of lossy lines with nonlinear loads requires the ability to compute and represent a suitable set of line impulse responses. In this paper, we propose the evaluation of the matched-line impulse responses by means of an algorithm for the numerical inversion of the Laplace Transform. Based on a discussion of the structure of the impulse responses, we demonstrate how...
متن کاملAnalysis of Time Response of Lossy Multiconductor Transmission Line Networks
Systems are considered consisting of an arbitrary number of multiconductor transmission lines joined and terminated by arbitrary linear networks. The fines are assumed to be Iossy, with frequency-dependent parameters. The system is analyzed in the frequency domain, and the inverse Fourier transform is used to obtain tbe time-domain response.
متن کاملLossy Transmission Line Modeling and Simulation Using Special Functions
A new algorithm for modeling and simulation of lossy interconnect structures modeled by transmission lines with Frequency Independent Line Parameters (FILP) or Frequency Dependent Line Parameters (FDLP) is developed in this research. Since frequency-dependent RLGC parameters must be employed to correctly model skin effects and dielectric losses for high-performance interconnects, we first study...
متن کاملObserver-Based Stabilizer of A single Machine Power System with Lossy Transmission Line
This paper proposes a stabilizing controller for single machine power system with nonzero conductance of transmission line. The proposed controller uses a reduced order observer to estimate the power angle of the system. The stability of the reduced order observer and that of the closed loop system incorporating the observer based stabilizer are given based on Lyapunov direct method. Simulation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Physics
سال: 1989
ISSN: 0002-9505,1943-2909
DOI: 10.1119/1.16053