An integrated calibration method for the cross-shaped magnetic gradiometer
نویسندگان
چکیده
The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, accuracy, and assembly technology. traditional methods calibrate error, misalignment the interference field independently. However, after long time work, calibration parameters will inevitably change. Furthermore, it waste lot manpower material resources if is disassembled calibrated step by step. Given above problems, novel attitude-independent algorithm using limited number points proposed, which can effectively overcome distortion does not rely reference magnetometer. For cross-shaped gradiometer, simulation results show that error integrated reduced to less than 8% before calibration. test suggest gradient are even up 1.5 µT/m, whereas 100 nT/m.
منابع مشابه
Direct string magnetic gradiometer for space applications
Recently, a novel Direct String Magnetic Gradiometer (DSMG) has been developed, where a vibrating wire, driven by an AC current, is used as a single sensitive element. It is designed to directly measure the local off-diagonal components of the magnetic gradient tensor, Bxz, Byz and Bxy, provided the distance to an object creating magnetic anomalies is much larger than the length of the string. ...
متن کاملReducing the magnetic susceptibility of parts in a magnetic gradiometer
The materials requirement inside a magnetic gradiometer is stringent because the presence of magnetic susceptible material will introduce intrinsic errors into the device. Many commercial grade non-magnetic materials still have unacceptably high levels of magnetic susceptibility between 10 and 10. It is shown here that machining with steel tools can further increase the susceptibility by up to ...
متن کاملAn optimized calibration method for surface measurements with MOSFETs in shaped-beam radiosurgery.
Nowadays MOSFET dosimeters are widely used for dose verification in radiotherapy procedures. Although their sensitive area satisfies size requirements for small field dosimetry, their use in radiosurgery has rarely been reported. The aim of this study is to propose and optimize a calibration method to perform surface measurements in 6 MV shaped-beam radiosurgery for field sizes down to 18 × 18 ...
متن کاملAn Integrated AHP-PROMETHEE Method for Selecting the most Suitable Ethylene Propylene Diene Termonomer
This paper considers the problem of selecting the most appropriate ethylene propylene diene monomer (EPDM), which is a polyolefin with a variety of usages in different areas. The metallocene catalyst, bis(2-phenyl indenyl) zirconium dichloride ((2-PhInd)2ZrCl2) was synthesized by a modified method and applied to the terpolymerization of ethylene, propylene, and 5-ethylidiene-2-norbornene (ENB)....
متن کاملArtificial Vector Calibration Method for Differencing Magnetic Gradient Tensor Systems
The measurement error of the differencing (i.e., using two homogenous field sensors at a known baseline distance) magnetic gradient tensor system includes the biases, scale factors, nonorthogonality of the single magnetic sensor, and the misalignment error between the sensor arrays, all of which can severely affect the measurement accuracy. In this paper, we propose a low-cost artificial vector...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIP Advances
سال: 2023
ISSN: ['2158-3226']
DOI: https://doi.org/10.1063/5.0161172