An inexpensive retrospective standard setting method based on item facilities
نویسندگان
چکیده
Abstract Background Standard setting is one of the most challenging aspects assessment in high-stakes healthcare settings. The Angoff methodology widely used, but poses a number challenges, including conceptualisation just-passing candidate, and time-cost implementing method. Cohen methodologies are inexpensive rapid rely on performance an individual candidate. A new method standard setting, based entire cohort every item, would be valuable. Methods We identified Borderline candidates by reviewing their across all assessments academic year. plotted item scores comparison with Facility for whole fitted curves to resulting distribution. Results It observed that any given Item, equation form y ≈ C. e Fx where x Item cohort, C F constants, predicts probable over test, other words, cut score candidates. describe ways estimating circumstance, suggest typical values arising from this particular study: = 12.3 0.021. Conclusions relatively stable, 12.3. 0.021x can rapidly applied item. average value represents as whole. This novel retrospective test takers. Compared which draws items test. propose it used set or predicted very different Facility.
منابع مشابه
Criterion Item Standard Setting
A method for establishing a minimum passing standard for a multiple choice test is described. The procedure is based on expert judgment about the content of test items. The method can also be used to monitor or adjust a standard that is already in place. The procedure carries advantages that are not available from other approaches to standard setting. It is easy to implement and easy for partic...
متن کاملAn Appropriate Theoretical Model for Developing Ambient Air Quality Standard in Iran Based on Standard Setting Approaches of Different Parts of the World
Background & objectives: Environmental standards are quantitative criteria for protecting the environment from pollution and degradation. One of the solutions to improve air quality status is to use reasonable limits to prevent excessive release of airborne contaminants from their various sources. On the other hand, these standards are effective in evaluating air pollution reduction strategies....
متن کاملAn inexpensive method of indirect ophthalmoscopy.
Attention is drawn to the possibility of performing monocular indirect ophthalmoscopy with a pen torch and a condensing lens when facilities for binocular indirect ophthalmoscopy are not available.
متن کاملImprovement in demand-controlled ventilation simulation on multi-purposed facilities under an occupant based ventilation standard
1569-190X/$ see front matter 2009 Elsevier B.V doi:10.1016/j.simpat.2009.09.009 * Corresponding author. Tel.: +82 2 3408 4037; fa E-mail address: [email protected] (J.-W. Jeong The objective of this paper was to find an effective way of improving demand-controlled ventilation (DCV) simulation performed under an occupant based ventilation standard established in many countries. Two attractive ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMC Medical Education
سال: 2021
ISSN: ['1472-6920']
DOI: https://doi.org/10.1186/s12909-020-02418-5