An incorrectly labelled Mallinckrodt double-lumen endobronchial tube

نویسندگان

چکیده

منابع مشابه

"Detachment of the carinal hook following endobronchial intubation with a double lumen tube"

BACKGROUND Carinal hooks increases difficulty at endotracheal intubation. Amputation of the carinal hook during passage and malpositioning of the tube to the hook are some of the potential problems related with left-sided Carlens double lumen tube (DLT). This article reports an amputation of the hook during a difficult selective intubation and aimed at calling the attention to complications ass...

متن کامل

Double Lumen Endotracheal Tube for Percutaneous Tracheostomy

BACKGROUND: Percutaneous dilational tracheostomy is normally a bronchoscope-guided procedure. The insertion of a bronchoscope into an endotracheal tube (ETT) affects resistance, flow, and alveolar pressure. To improve airway management and ventilation during percutaneous tracheostomy, we developed a double lumen endotracheal tube (DLET). The aim of this in vitro study was to compare the linear ...

متن کامل

Double lumen endotracheal tube for percutaneous tracheostomy?

BACKGROUND Percutaneous dilational tracheostomy is normally a bronchoscope-guided procedure. The insertion of a bronchoscope into an endotracheal tube (ETT) affects resistance, flow, and alveolar pressure. To improve airway management and ventilation during percutaneous tracheostomy, we developed a double lumen endotracheal tube (DLET). The aim of this in vitro study was to compare the linear c...

متن کامل

Comparison of the resistances of double-lumen endobronchial tubes.

The resistance of commonly-used double-lumen endobronchial tubes were measured and a detailed comparison made. Robertshaw tubes were generally found to have a lower resistance than either the Carlens or the White tubes of equivalent size, but this was not so in every case. The White tubes had a disproportionately high resistance associated with the upper lobe orifice when compared with the resi...

متن کامل

Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes.

T here are no objective criteria for selecting the size of a double-lumen endobronchial tube (DLT) (1). An inappropriately sized DLT can cause airway trauma and interfere with oxygenation and lung separation during one-lung ventilation. The goal of this study was to determine if measurement of tracheal diameter from the preoperative chest radiograph can be used to predict which size DLT to choo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia

سال: 1994

ISSN: 0003-2409,1365-2044

DOI: 10.1111/j.1365-2044.1994.tb04436.x