An Improved Vibration-Insensitive Spherical Optical Cavity

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibration Insensitive Interferometric Optical Testing

The measurement accuracy of an interferometric optical test is generally limited by the environment. This paper discusses two single-shot interferometric techniques for reducing the sensitivity of an optical test to vibration; simultaneous phase-shifting interferometry and spatial carrier interferometry. ©2004 Optical Society of America OCIS codes: (120.0120) Instrumentation, measurement and me...

متن کامل

State-insensitive cooling and trapping of single atoms in an optical cavity.

Single cesium atoms are cooled and trapped inside a small optical cavity by way of a novel far-off-resonance dipole-force trap, with observed lifetimes of 2-3 s. Trapped atoms are observed continuously via transmission of a strongly coupled probe beam, with individual events lasting approximately 1 s. The loss of successive atoms from the trap N>/=3-->2-->1-->0 is thereby monitored in real time...

متن کامل

Particle creation in an oscillating spherical cavity

We study the creation of massless scalar particles from the quantum vacuum due to the dynamical Casimir effect by spherical shell with oscillating radius. In the case of a small amplitude of the oscillation, to solve the infinite set of coupled differential equations for the instantaneous basis expansion coefficients we use the method based on the time-dependent perturbation theory of the quant...

متن کامل

Improved measurement of vibration amplitude in dynamic optical coherence elastography

Optical coherence elastography employs optical coherence tomography (OCT) to measure the displacement of tissues under load and, thus, maps the resulting strain into an image, known as an elastogram. We present a new improved method to measure vibration amplitude in dynamic optical coherence elastography. The tissue vibration amplitude caused by sinusoidal loading is measured from the spread of...

متن کامل

Vibration insensitive extended range interference microscopy.

Using a simultaneous phase sensor, the proposed instrument performs highly repeatable measurements over an extended range in the presence of vibration common to a laboratory setting. Measurement of a 4.5 μm step standard in the presence of vibration amplitudes of 40 nm produces a repeatability of 1.5 nm RMS with vertical scanning data acquired at 400 nm intervals. The outlined method demonstrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Modern Physics

سال: 2018

ISSN: 2161-0916,2161-0924

DOI: 10.12677/mp.2018.82005