Determination of fluoride in wine by fluoride selective ion electrode, standard addition method: collaborative study.

The accuracy, precision, and reproducibility of a rapid method for determination of fluoride in wine, using a fluoride selective ion electrode, were established by a collaborative study involving 12 laboratories, 5 in Europe and 7 in the United States. The laboratories assayed 6 Youden pairs of fluoride-fortified, red and white wine samples with fluoride concentrations ranging from 0.2 to 3.0 m...

متن کامل

Lithium determined in serum with an ion-selective electrode.

We evaluated the performance of the lithium ion-selective electrode (ISE) in the Du Pont Na/K/Li analyzer. Lithium concentrations in 106 serum samples from patients being treated with lithium were measured in duplicate with the ISE and by flame photometry. The slope of the regression line for the two methods was 1.004 with a standard error of the estimate of 0.049 mmol/L (x = flame photometry, ...

متن کامل

Determination of fluoride in black, green and herbal teas by ion- selective electrode using a standard-addition method

Tea leaves are very rich in fluoride, since tea plants take up fluoride from the soil and accumulate in its leaves. Some of this fluoride is released into the infusion, which is drunk as tea. Fluoride in tea could be beneficial for the prevention of dental caries, but it may result in excessive intake and lead to enamel fluorosis. The purpose of this work was to determine the fluoride levels in...

متن کامل

Analysis for potassium in human erythrocytes by use of a standard-additions method and an ion-selective electrode.

A method based on standard additions to the sample was used to measure potassium (K+) in human erythocytes with an ion-selective electrode. A computer program was developed for rapid analysis of data obtained with the electrode. The analysis takes into account factors such as temperature that may affect electrode behavior. Results obtained by the method agree with those obtained by flame-emissi...

متن کامل

Measurements with fluoride ion selective electrode

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...