An Improved Quasi-Resonant Controller for Grid-Connected Inverter with LCL Filter
نویسندگان
چکیده
منابع مشابه
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter wi...
متن کاملA Harmonic Compensation Strategy for Grid-connected Inverter with LCL Filter
LCL filter has the characteristic of prompt attenuation over the high-frequency range, but the thirdorder control system exits the resonance problem. Nonetheless, the inherent non-linear characteristic and dead-time effects of switching tubes, along with the DC-side voltage secondary pulsation and grid harmonic pollution, arouse a wealth of low-order harmonics injected which is tough to be filt...
متن کاملResonant Characteristics Analysis and Suppression Strategy of Multiple Parallel Grid-connected Inverters with LCL Filter
The multiple parallel inverters have more than one resonant frequency influenced by many factors, which tends to result in stability and power quality problems. This paper develops the multiple input multiple output model of the grid-connected inverters system using the closed-loop transfer function. The influence factors of resonant characteristics are analyzed with the developed model. The an...
متن کاملThree-phase LCL-filter for Grid-connected Inverter Using Cooperative Bacteria Foraging Optimization
This paper establishes an LCL-filters design and control for three-phase grid inverter. The crucial object is to conquer optimum damping with a required system control bandwidth for the LCL-filter. This control technique is achieved by using Bacteria Foraging Optimization. Mathematical analysis has been introduced to investigate the steady-state and dynamic performances of the overall system. T...
متن کاملDesign of Grid connected Photovoltaic Inverter with Resonant Harmonic Compensator
The reduction of high harmonic content in the grid side current is achieved by different harmonic compensating techniques. In order to accomplish it, selective harmonic compensation is carried out in grid-connected photovoltaic inverters by means of resonant harmonic compensators. The harmonic compensator shown in this paper is lead lag compensator. This paper shows a systematic design procedur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2021
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1735/1/012006