An improved fault tolerant for a five-phase induction machine under open gate transistor faults
نویسندگان
چکیده
منابع مشابه
Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open
This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in orde...
متن کاملFault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملInvestigating Direct Torque Control of Six-Phase Induction Machines Under Open Phase Fault Conditions
This paper presents analysis and evaluation of classical direct torque control(DTC), for controlling a symmetrical six phase induction motor (SPIM) under open phasefault conditions. The machine has two three-phase windings spatially shifted by 60 electricaldegrees. The strategy of the proposed method consists of choosing the switching modesaccording to the configuration of living phases in such...
متن کاملdevelopment and implementation of an optimized control strategy for induction machine in an electric vehicle
in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...
15 صفحه اولSimplified Minimum Copper Loss Remedial Control of a Five-Phase Fault-Tolerant Permanent-Magnet Vernier Machine under Short-Circuit Fault
Abstract: A fault-tolerant permanent-magnet vernier (FT-PMV) machine incorporates the merits of high fault-tolerant capability and high torque density. In this paper, a new remedial control is proposed for a five-phase FT-PMV machine with short-circuit fault of stator windings. Based on the principle of copper loss minimization, the aims of the proposed control strategy are to keep magnetic mot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Alexandria Engineering Journal
سال: 2016
ISSN: 1110-0168
DOI: 10.1016/j.aej.2016.04.040