An Improved Droop Control Strategy for Low-Voltage Microgrids Based on Distributed Secondary Power Optimization Control
نویسندگان
چکیده
منابع مشابه
An Improved Droop Control Strategy for Low-Voltage Microgrids Based on Distributed Secondary Power Optimization Control
To achieve accurate reactive power sharing and voltage frequency and amplitude restoration in low-voltage microgrids, a control strategy combining an improved droop control with distributed secondary power optimization control is proposed. The active and reactive power that each distributed generator (DG) shares is calculated by extracting load information and utilizing a power sharing ratio, a...
متن کاملAn Improved Droop Control Strategy Based on Changeable Reference in Low-Voltage Microgrids
This paper proposes an improved droop control strategy based on changeable reference in low-voltage microgrids. To restore running frequency of distributed generation to a rated value without affecting its reactive power output, changeable frequency reference, mainly compensating for frequency deviation, are proposed corresponding to various load demands. In terms of active power sharing inaccu...
متن کاملA Robust Control Strategy for Distributed Generations in Islanded Microgrids
This paper presents a robust control scheme for distributed generations (DGs) in islanded mode operation of a microgrid (MG). In this strategy, assuming a dynamic slack bus with constant voltage magnitude and phase angle, nonlinear equations of the MG are solved in the slack-voltage-oriented synchronous reference frame, and the instantaneous active and reactive power reference for the slack bus...
متن کاملDistributed Nonlinear Robust Control for Power Flow in Islanded Microgrids
In this paper, a robust local controller has been designed to balance the power for distributed energy resources (DERs) in an islanded microgrid. Three different DER types are considered in this study; photovoltaic systems, battery energy storage systems, and synchronous generators. Since DER dynamics are nonlinear and uncertain, which may destabilize the power system or decrease the performanc...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2017
ISSN: 1996-1073
DOI: 10.3390/en10091347