An Experimental Study on Current Unbalance in High Current Capacity Superconducting AC/Pulse Conductor
نویسندگان
چکیده
منابع مشابه
Study of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملAn Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques
The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...
متن کاملToxicity of Nanoparticles and an Overview of Current Experimental Models
Nanotechnology is a rapidly growing field having potential applications in many areas. Nanoparticles (NPs) have been studied for cell toxicity, immunotoxicity, and genotoxicity. Tetrazolium-based assays such as MTT, MTS, and WST-1 are used to determine cell viability. Cell inflammatory response induced by NPs is checked by measuring inflammatory biomarkers, such as IL-8, IL-6, and tumor necrosi...
متن کاملEffect of Intra-Canal Direct Current Electric Stimulation on Orthodontic Tooth Movement: An Experimental Study in Canines
Objectives: The purpose of this study was to evaluate whether intra-canal application of controlled direct electric current (DEC) could accelerate the amount of orthodontic tooth movement (OTM) in young adult mixed breed dogs. Methods: Fourth premolars of both jaws of five young adult mixed breed dogs were divided into two groups of control and experimental groups. Orthodontic force...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Fundamentals and Materials
سال: 1995
ISSN: 0385-4205,1347-5533
DOI: 10.1541/ieejfms1990.115.3_233