An Experimental Study on Cooling of CPU using a Two Phase Closed Thermosyphon Loop
نویسندگان
چکیده
منابع مشابه
Experimental Investigation of Boiling and Condensation Heat Transfer of a two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of the thermosyphon. The experimental boiling and condensation heat transfer coefficients inside the thermosyphon were com...
متن کاملExperimental Investigation of Boiling and Condensation Heat Transfer of a Two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of a thermosyphon with a copper tube having 25 and 32 mm inside and outside diameters. Distilled water was used as the wor...
متن کاملTwo-phase Closed Thermosyphon with Nanofluids
Nanofluids, stabilized suspensions of nanoparticles typically < 100 nm in conventional fluids, are evolving as potential enhanced heat transfer fluids due to their better thermal conductivity, increase in single phase heat transfer coefficient and significant increase in critical boiling heat flux. In the present paper, we investigate the overall thermal resistance of a closed two-phase thermos...
متن کاملApplication of a two-phase thermosyphon loop with minichannels and a minipump in computer cooling
This paper focuses on the computer cooling capacity using the thermosyphon loop with minichannels and minipump. The one-dimensional separate model of two-phase flow and heat transfer in a closed thermosyphon loop with minichannels and minipump has been used in calculations. The latest correlations for minichannels available in literature have been applied. This model is based on mass, momentum,...
متن کاملDiffusion Induced Chaos in a Closed Loop Thermosyphon
The dynamics of a closed loop thermosyphon are considered. The model assumes a prescribed heat flux along the loop wall and the contribution of axial diffusion. The well-posedness of the model which consists of a coupled ODE and PDE is shown for both the case with diffusion and without diffusion. Boundedness of solutions, the existence of an attractor, and an inertial manifold is proven, and an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
سال: 2004
ISSN: 0387-5016,1884-8346
DOI: 10.1299/kikaib.70.1504