Full Analysis of Low Finned Tube Heat Exchangers
In this paper, first the governing parameters characterizing low-finned tubes are reviewed. Second, the more important of the available performance correlations are compared with the available experimental data. The most reliable one can be employed to develop a pressure drop relationship, which has already been used in an algorithm for exchanger sizing. Also a means for the identification of a...
متن کاملExperimental and simulation study on the air side thermal hydraulic performance of automotive heat exchangers
Flat tube heat exchangers with louvered fins were applied in order to meet the performance requirements and compactness in automotive air conditioning systems. Experimental and simulation study focusing on the air side thermal hydraulic performance of automotive heat exchangers were performed in this article. Test results showed that the heat capacity of a condenser with 5.4 mm height louvered ...
متن کاملAn Experimental Study of Nanofluids Operated Shell and Tube Heat Exchanger with Air Bubble Injection
Shell and Tube heat exchangers are the heat exchangers that are most widely used in industries and for other commercial purposes. There are many techniques that have been utilized to enhance the heat transfer performance of the shell and tube heat exchangers. Air bubble injection is one of the promising and inexpensive techniques that can create turbulence in the fluids resulting in to enhancem...
متن کاملAir-side Particulate Fouling of Microchannel Heat Exchangers: Experimental Comparison of Air-Side Pressure Drop and Heat Transfer with Plate-Fin Heat Exchanger
In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing the air-...
متن کاملAn Experimental Investigation of Thermoelectric Air-Cooling Module
This article experimentally investigates the thermal performance of thermoelectric air-cooling module which comprises a thermoelectric cooler (TEC) and an air-cooling heat sink. The influences of input current and heat load are determined. And performances under each situation are quantified by thermal resistance analysis. Since TEC generates Joule heat, this nature makes construction of therma...