An examination of organ equivalent and effective doses from diagnostic radiology procedures

نویسندگان

چکیده

The quantification of radiation risks associated with radiological examinations has been a subject interest the increased use X-rays. Effective dose, which is risk-weighted measure to organs in body examination, considered good indicator risk. We have therefore investigated patient effective doses from examinations. Organ and were estimated for 94 patients who underwent computed tomography 338 had conventional radiography Org Dose (version 2) program was used estimation doses. tube potential ranges: 57 kVp 138 depending on examination size. entrance surface wide range even same examination: 0.44-10.31 mGy (abdomen) 0.66-16.08 (lumbar spine) corresponding dose ranges 0.025-0.77 mSv 0.025-0.95 respectively. adult abdomen-pelvic CT 5.4-19.8 mean 13.6 pediatrics 2.1-5.5 2.7 mSv. chest head are 7.9 1.8 respectively 1.7 1.1

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures

The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays. Effective dose, which is a risk-weighted measure of radiation to organs in the body associated with radiological examination, is considered a good indicator of radiological risk. We have therefore investigated patient effective doses from radiological ...

متن کامل

Effective doses in radiology and diagnostic nuclear medicine: a catalog.

Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007, medical uses represent the largest source of exposure to the U.S. population. Most physicians have difficulty assessing the magnitude of exposure or potential risk. Effective dose provides an approximate indicator of potential detriment from ionizing radiation and should be used as one parameter in evaluati...

متن کامل

Interventional Radiology: Vascular Diagnostic and Therapeutic Procedures

For the most part, a system of component coding is used in these cases, in order to accurately describe the separately identifiable surgical and imaging services performed by the radiologist. In this way, the Current Procedural Terminology (CPT) code structure recognizes that there can be variations in the services performed during diagnostic angiography and vascular transcatheter therapies, wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International journal of radiology and diagnostic imaging

سال: 2021

ISSN: ['2664-4436', '2664-4444']

DOI: https://doi.org/10.33545/26644436.2021.v4.i2b.310