AN EFFECTIVE WAY TO PREPARE POLYETHYLENE GLYCOL-MODIFIED GRAPHENE OXIDE
نویسندگان
چکیده
منابع مشابه
Polyethylene glycol rinse solution: an effective way to prevent ischemia-reperfusion injury.
AIM To test whether a new rinse solution containing polyethylene glycol 35 (PEG-35) could prevent ischemia-reperfusion injury (IRI) in liver grafts. METHODS Sprague-Dawley rat livers were stored in University of Wisconsin preservation solution and then washed with different rinse solutions (Ringer's lactate solution and a new rinse solution enriched with PEG-35 at either 1 or 5 g/L) before ex...
متن کاملSensitive measurement of polyethylene glycol-modified proteins.
An IgM monoclonal antibody (AGP3) against polyethylene glycol (PEG) was used to assay PEG-modified proteins by ELISA. PEG-modified beta-glucuronidase could be measured at concentrations as low as 15 ng/mL, corresponding to 750 pg (1.8 fmol) of conjugate. This ELISA should be generally applicable to all PEG-modified proteins because AGP3 binds the backbone of the PEG chain independent of the lin...
متن کاملPlasma expansion by polyethylene-glycol-modified albumin.
Systemic inflammatory response conditions are associated with capillary leak and haemodynamic compromise. Fluid resuscitation to reverse the ensuing hypovolaemia is, however, complicated by the decreased endothelium reflection coefficient to albumin and other colloids. We developed PEG-Alb (albumin covalently linked to polyethylene glycol) as a potential resuscitative agent. PEG was covalently ...
متن کاملhemoglobin modified with maleimide - activated polyethylene glycol
We have recently described human hemoglobin surfacemodified with polyethylene glycol (MP4, registered trademark Hemospan) that does not possess the vasoconstrictive properties which have hampered development of some hemoglobin-based oxygen carriers. Based on in vitro studies, we postulated that this lack of vasoconstriction is due to decreased diffusive oxygen transfer in the plasma space as a ...
متن کاملStabilization of ssRNA on graphene oxide surface: an effective way to design highly robust RNA probes.
RNA probes constitute an important class of functional nucleic acids (FNAs). However, because of their notorious vulnerability to enzymatic degradation, extremely careful and special protocols must be followed when dealing with RNA probes. To fully use the large number of RNA FNAs available for bioanalysis and biomedicine, it is important to explore effective methods to protect RNA probes from ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Polymerica Sinica
سال: 2012
ISSN: 1000-3304
DOI: 10.3724/sp.j.1105.2012.11335