An application of threshold-versus-intensity functions in automated static perimetry
نویسندگان
چکیده
منابع مشابه
An application of threshold-versus-intensity functions in automated static perimetry
Increment thresholds were measured over a range of adapting illuminances using a modified automated static perimeter. The data were fitted to a threshold versus intensity model (logT - logT(0) + log((A + A(0))/A(0))n) and the values logT(0) and logA(0) estimated. The effect of eccentricity and age on logT(0) and logA(0) was examined in normal subjects. A small group of patients with ocular dise...
متن کاملFatigue effects during a single session of automated static threshold perimetry.
PURPOSE To determine using a routine clinical program the time course of the fatigue effect in both eyes at a given examination, the influence of rest periods during the examination, and the differences in the fatigue effect between persons with ocular hypertension and age-matched normal subjects. METHODS Perimetry was undertaken for both eyes of 20 normal persons and 20 persons with ocular h...
متن کاملrecent developments in automated perimetry
modern computerized technology enables more complex visual stimuli and test procedures to be in-corporated into conventional perimetry resulting in several developments in automated perimetry that have contributed to more efficient diagnosis and management of eye diseases. this review will cover a number of advances in automated perimetry including frequency doubling technology perimetry, short...
متن کامل1235 High-pass resolution perimetry vs static threshold perimetry in advanced primary open-angle glaucoma
PURPOSE: To compare Static Threshold Perimetry (Humphrey 30.2) with High-pass Resolution Perimetry (Ophthimus) for the assessment of Visual Field W.F.) defects in uatients with advanced glaucomatous damage. METHODS: Patient selection criteria: Primary Open-angle Glaucoma, advanced V.F. damage (MD > 5 dB) visual acuity > 20/70. previous experience in V.F. testing: 38 eyes were selected for the s...
متن کاملComparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Vision Research
سال: 2005