An analytical solution of distortional buckling resistance of cold-formed steel channel-section beams with web openings

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distortional Buckling Tests on Cold-Formed Steel Beams

Failure in cold-formed steel beams is generally initiated by one of three instabilities: local, distortional, or lateral-torsional buckling. For cold-formed steel joists, purlins, or girts, when the compression flange is not restrained by attachment to sheathing or paneling, distortional buckling may be the predominant failure mode. Experimental results on cold-formed steel beams with unrestrai...

متن کامل

Local and Distortional Buckling of Cold-Formed Steel Members

Laminar structures have a high post-buckling strength reserve. Cold-formed steel profiles can be taken as a set of thin plate elements. Therefore it is necessary to design this type of profiles taking into account that reserve of strength in post-local buckling modes of failure. The method normally used to design this type of structures is based on the Effective Width concept. The Effective Wid...

متن کامل

Comparative Study on Distortional Buckling Strength of Cold-Formed Steel Lipped Channel Sections

Usage of cold formed steel structural components for buildings and structures is gaining popularity in India for a decade. Hot rolled steel member behaviour and design are well developed, whereas the cold formed steel member behaviour and design is not developed fully compared to the rest of the world. The Indian code for cold-formed steel design, IS 801 was revised during 1975, which is in lin...

متن کامل

Steel Beams with Web Openings

The responsibility of a Structural Engineer lies in not merely designing the structure based on safety and serviceability considerations but he also has to consider the functional requirements based on the use to which the structure is intended. While designing a power plant structure or a multi-storeyed building, the traditional structural steel framing consists of beams and girders with solid...

متن کامل

Local Buckling Tests on Cold-Formed Steel Beams

C and Z sections are two of the most common cold-formed steel shapes in use today. Accurate prediction of the bending performance of these sections is important for reliable and efficient cold-formed steel structures. Recent analytical work has highlighted discontinuities and inconsistencies in the American Iron and Steel Institute ~AISI! and Canadian Standards Association ~S136! design provisi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thin-Walled Structures

سال: 2019

ISSN: 0263-8231