An Advanced Calibration Method for Probe Leakage Correction in On-Wafer Test Systems
نویسندگان
چکیده
This article presents an advanced calibration method for solving the error terms due to probe-probe leakage in on-wafer test system. A new 12-term model system including vector network analyzer (VNA), frequency extenders, cables/waveguides, probes, probe contact pads and is introduced. two-step process algorithm with four on-chip standards one undefined Thru, two pairs of symmetrical Reflects such as Open-Open Short-Short pairs, a pair known Match loads has been developed. In addition, improved circuit load proposed enhanced accuracy. The tested on mismatched attenuator range between 0.2 110 GHz, results are compared numerical simulation existing methods. It shown that attenuator’s $\vert S_{11}\vert $ more consecutive S_{21}\vert by up-to 1.7 dB. evident simpler less stringent requirements which key at millimeter-wave terahertz frequencies. More importantly, suitable measurements DUTs have variable lengths.
منابع مشابه
Test Structures and Techniques for On-Wafer CMOS TRL Calibration
In this paper, we demonstrate for the first time a TRL calibration kit fabricated in CMOS technology. To fulfill a basic requirement of high probe-isolation of the TRL method, we have based all fabricated calibration standards on a shield-based measuring fixture that heavily reduces the effects of the semiconducting substrate. We analyze the electrical performance of the standards, including th...
متن کاملCalibration curves for on-line leakage detection using radiotracer injection method
One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...
متن کاملAdvanced Wafer Thinning Technology and Feasibility Test for 3D Integration
Introduction The semiconductor industry is now facing a major turning point in how to realize the next generation of large-scale integration. Recently 3D integration (3DI) using through-silicon via (TSV) has widely studied and wafer thinning has been considered to be a promising technology for enhancing system performance instead of conventional two-dimensional (2D) scaling due to technical and...
متن کاملAdvanced Calibration Method for Pitch Artifact
Abstract − The pitch measuring accuracy for gear measuring instruments (GMIs) is evaluated by measuring a calibrated artifact. We proposed a novel artifact which called multiball artifact (MBA). The MBA is composed of the pitch balls assumed to gear teeth and the reference axis assumed to a center axis of gear. The MBA can be calibrated more accurate than a conventional pitch artifact. When the...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Microwave Theory and Techniques
سال: 2023
ISSN: ['1557-9670', '0018-9480']
DOI: https://doi.org/10.1109/tmtt.2022.3200050