An active reflector antenna using a laser angle metrology system
نویسندگان
چکیده
منابع مشابه
Theoretical Analysis of Polarization Rotation angle in Dual Reflector Antenna
Because of special structure, a dual reflector antenna has beam rotation capability in azimuth and elevation directions. In this structure, the antenna beam can be placed in any point in the space by mechanical movement of twist reflector which it is the most important ability of the antenna. Due to the antenna structure, if the polarization of incident wave is linear, it is expected that the p...
متن کاملOn the design of a reflector antenna
We consider the problem of recovering a reflecting surface such that for a given point source of light the directions of the reflected rays cover a prescribed region of a far field sphere and the density of the distribution of the reflected rays is a function prescribed in advance, where the aperture of the incident ray cone is also prescribed in advance. Mathematically this problem requires on...
متن کاملThree-Dimensional Comer Reflector Antenna
A reflector antenna utilizing three planar reflectors and a 3/4 X-unipole radiator is proposed. Calculations based on image and EMF-methods predict that the gain is about 5 dB greater than that of the two-dimensional comer reflector antenna, and that the input impedance is roughly between 50 and 75 9. Experiments conducted on the three-dimensional corner reflector antenna with rectangular comer...
متن کاملDesign of Dual Reflector Cassegrain Feed System Antenna
This paper introduces a Design of dual reflector Cassegrain feed system antenna with suitable design aspects like smaller reflector and sub reflector diameter for higher sub reflector efficiency, lower Cassegrain blockage losses and desired illumination taper. Design parameters are computed from the simple and explicit analytical formulas. Design example is represented to differentiate the effi...
متن کاملOcular microtremor measurement using laser-speckle metrology.
We describe a novel, noninvasive measurement approach for recording a small involuntary tremor of the eye known as ocular microtremor. The method is based on measuring out-of-plane angular displacements of a target by using laser-speckle correlation of images recorded in the Fourier plane of a lens. The system has a dynamic range of 4 to 5000 μrad, resolution of 4 μrad, and a bandwidth of 250 H...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Research in Astronomy and Astrophysics
سال: 2012
ISSN: 1674-4527
DOI: 10.1088/1674-4527/12/6/011