Amperometric tape ion sensors for cadmium(II) ion analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lithium Ion Sensors

The detection and monitoring of lithium in environmental and clinical settings is becoming increasingly important. In this review, sensors incorporating conductive polymers and lithium bronzes are discussed, together with electrochemical and spectroscopic approaches. Ionophore-based methods have been employed extensively, with varying degrees of selectivity and sensitivity, and these are discus...

متن کامل

How Do Pulsed Amperometric Ion Sensors Work? A Simple PDE Model

The heat equation posed on the half-line may be used as a simple mathematical model describing the operation of an amperometric ion sensor. These sensors represent the next generation of sensors that are in routine use today. Such sensors may be used to measure ion concentrations in the laboratory, for clinical analysis, environmental monitoring, process and quality control, biomedical analysis...

متن کامل

Amperometric proton selective sensors utilizing ion transfer reactions across a microhole liquid/gel interface.

A new cost-effective amperometric proton selective sensor utilizing a single microhole interface between two immiscible electrolyte solutions (ITIES) is developed. The sensing methodology is based on measuring currents associated with proton transfer across the interface assisted by a proton selective ionophore. The ellipse shaped micro-interface was first fabricated by simple mechanical punchi...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Amperometric Sensors for the Analysis of the Oxygen Content

The paper presents the using of amperometric sensors in measurements of the oxygen content in the organic solutions such as beer. The resulted data compared with spectrophotometric data.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Talanta

سال: 2009

ISSN: 0039-9140

DOI: 10.1016/j.talanta.2008.10.059