Ammonium sulfate crystallization in Andersen cascade impactor samples

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Andersen Impactor: Calibration, Wall Losses and Numerical Simulation

-Andersen cascade impactors are widely used to assess airborne particle size distributions. Two forms (MkI and MklI) have been calibrated using solid and liquid aerosols, measured by microscopy, fluorimetry, and aerodynamic particle sizer. A fluorescent tracer was used to examine qualitatively the details of the wall loss deposition patterns when using greased and ungreased plates, and to quant...

متن کامل

Ammonium Chloride and Ammonium Sulfate in Cattle Feedlot Finishing Rations

T WO levels of ammonium chloride or of ammonium sulfate were added to the rations of commercial feeder cattle. The rations were made isonitrogenous, essentially isocaloric and to contain the same level of calcium, phosphorus and salt. Total gains were essentially the same for all lots, varying only 15.6 lb (7.1 kg) over a 112 day feeding period. Feed conversion was increased only on the ration ...

متن کامل

Deposition Dosages of Three Cromolyn Forms by Cascade Impactor

Among inhaled asthma therapies, the present study aimed to identify factors for selecting the type of inhalation therapy for asthma. Three methods are used to deliver inhaled cromoglycate, and the airway deposition rate was evaluated using a cascade impactor with 3 dosage forms: dry powder (DP), pressurized metered dose inhaler (pMDI), and solution (jet- and mesh-types). The percentage of parti...

متن کامل

Medical nebulizer performance: effects of cascade impactor temperature.

BACKGROUND During operation of a jet nebulizer, the temperature of the nebulizer outlet could decrease by more than 10 degrees C, depending on the nebulizer type and operating conditions, such as driving flow rate and fill volume. The droplet size distribution generated from the nebulizer can be measured by a cascade impactor. However, when the cascade impactor is operated at ambient room tempe...

متن کامل

Ammonium sulfate – malonic acid aerosols

A study of the phase transition behavior of mixed ammonium sulfate – malonic acid aerosols C. F. Braban and J. P. D. Abbatt Centre for Atmospheric Sciences, Department of Chemistry, Lensfield Road, University of Cambridge, Cambridge, CB2 1EW, UK Department of Chemistry, University of Toronto, Toronto, ON, M5S 3H6, Canada Received: 22 March 2004 – Accepted: 3 May 2004 – Published: 2 June 2004 Co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Atmospheric Environment (1967)

سال: 1974

ISSN: 0004-6981

DOI: 10.1016/0004-6981(74)90046-8