Aluminium removal with the double chamber technique: paired filtration-dialysis (PFD)

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INTERFERENCE OF ALUMINIUM WITH CARBOHYDRATE METABOLISM IN MALE RATS: A MODEL STUDY OF DIALYSIS PATIENTS

The effects of aluminium and aluminium-citrate on some serum parameters related to carbohydrate metabolism in male Wistar rats were investigated. Daily intraperitoneal administrations of 1 mg/kg body weight of aluminium or aluminiumcitrate (1: 1) for 50 days led to the elevation of serum insulin by 24 or 40 percent respectively, with the concomitant decrease in serum glucose concentrations ...

متن کامل

The mechanisms of leukocyte removal by filtration.

C ONVINCING evidence exists that blood transfusions are associated with deleterious effects caused by residual leukocytes in blood and blood components. These side effects include alloimmunization to histocompatibility antigens, transmission of viruses, immunosuppression and graft-versus-host disease (GVHD). Leukocyte depletion of blood components may prevent or ameliorate some of these harmful...

متن کامل

New pH-neutral peritoneal dialysis solution, low in glucose degradation products, in a double-chamber bag.

Fresenius Medical Care-North America has developed a neutral-pH version of its Delflex peritoneal dialysis (PD) solution with low glucose degradation products (GDPs): Delflex Neutral pH. The Delflex Neutral pH system stores the PD solution in a dual-chamber bag. The product is admixed by the patient before use. The new design facilitates GDP reduction in two ways. First, GDPs are reduced becaus...

متن کامل

Hemolysis in double-filtration plasmapheresis.

To evaluate the occurrence of hemolysis during double-filtration plasmapheresis (DFP) treatment and its causes, we prospectively treated 113 myasthenic patients and monitored transmembrane pressure (TMP), arterial line pressure (Pa), and venous line pressure (Pv) at 30-minute intervals (M30, M60, M90, and M120) during treatment. Laboratory and clinical parameters related to the development of h...

متن کامل

Comparison of PFD calculation

Safety systems are be used in a wide range of technical application. Beside the availability of such systems the safety aspects, e. g. PFD and PFH figures, must be observed. Especially the calculation of these figures requires the use of standards. Worldwide are standards available for this calculation. The newest standard is IEC 61508. This standard is worldwide accepted. Another standard, whi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nephrology Dialysis Transplantation

سال: 1998

ISSN: 1460-2385

DOI: 10.1093/ndt/13.suppl_3.82