Alternative Identification Method using Biased Relay Feedback
نویسندگان
چکیده
منابع مشابه
Pi Autotuners Based on Biased Relay Identification
The paper describes an automatic tuning procedure for a wide class of continuous-time systems without and with time delays. Every auto-tuning method has two basic steps. The first one is experimental and yields an estimated model. The second step consists in a design procedure of controllers. The developed auto-tuning procedure identifies a first order estimation model obtained by a biased rela...
متن کاملProcess Identification Using Relay Feedback with a Fractional Order Integrator
In this work, a novel relay feedback experiment method is proposed for system identification by connecting a fractional order integrator in front of a basic relay component. With this approach, a linear time invariant process model can be estimated at an arbitrary phase angle in the third or fourth quadrant on the Nyquist curve. Another contribution of this paper is to present a pseudo frequenc...
متن کاملRelay Feedback: Analysis, Identification and Control
REFERENCES [1] S. Kay, Fundamentals of Statistical Signal Processing, Volume 1, Estimation Theory. Englewood Cliffs, NJ: Prentice Hall, 1993. [2] S. Kay, Fundamentals of Statistical Signal Processing, Volume 2, Detection Theory. Englewood Cliffs, NJ: Prentice Hall, 1998. [3] A. Leon-Garcia, Probability and Random Processes for Electrical Engineering, 2nd ed. Reading, MA: Addison-Wesley, 1994. [...
متن کاملPlant identification by relay method
Plant identification is very important in control design. The relay method belongs among special kinds of experimental frequency response identification. It was originally used for plant identification by Rotach (Rotač, 1964) and lately also for controller autotuning, see reference (Åstrőm & Wittenmark, 1989; Åstrőm, 1993; Åstrőm & Hägglund, 1995; Bi et al., 1997; Hang et al., 1993; Lu et al., ...
متن کاملShifting Method for Relay Feedback Identification and Control of Delayed Systems
The paper deals with identification and control of time delay stable plants. A single relay feedback test and the new method called “shifting method” are used for plant identification. For this purpose an asymmetric relay is used. This approach enables to estimate three points on a plant frequency response for three important frequencies from sustained oscillations obtained by a single relay te...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IFAC-PapersOnLine
سال: 2018
ISSN: 2405-8963
DOI: 10.1016/j.ifacol.2018.08.491