All-Solid-State Polymeric Membrane Ion-Selective Miniaturized Electrodes Based on a Nanoporous Gold Film as Solid Contact
نویسندگان
چکیده
منابع مشابه
Multi-analyte biochip (MAB) based on all-solid-state ion-selective electrodes (ASSISE) for physiological research.
Lab-on-a-chip (LOC) applications in environmental, biomedical, agricultural, biological, and spaceflight research require an ion-selective electrode (ISE) that can withstand prolonged storage in complex biological media (1-4). An all-solid-state ion-selective-electrode (ASSISE) is especially attractive for the aforementioned applications. The electrode should have the following favorable charac...
متن کاملAll-solid-state potassium-selective electrode using graphene as the solid contact.
Graphene sheets are used for the first time to fabricate a new type of solid-contact ion-selective electrode (SC-ISE) as the intermediate layer between an ionophore-doped solvent polymeric membrane and a glassy carbon electrode. The new transducing layer was characterized by transmission electron microscopy, scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectros...
متن کاملMulti-walled Carbon Nanotubes as Ion-to-Electron Transducer in All-Solid-State Potassium Ion-Selective Electrodes
Carbon nanostructured materials in general and carbon nanotubes in particular exhibit remarkable and unique properties that make them promising candidates for a wide range of applications. In the field of sensors, for example, carbon-based materials such as fullerene (C60) [1], three-dimensionally ordered macroporous (3DOM) carbon [2], and single-walled carbon nanotubes (SWCNTs) [3] have been u...
متن کاملA Solid-state Silver Ion Selective Electrode Based on Polyaniline/Eosin Y Nanocomposite Film
Potentiometric sensor based on commercial pencil graphite electrodes coated with polyaniline (PAni) composite with Eosin Y (EY) termed as PGE/PAni-EY have been developed for potentiometric determination of silver ion. The electrode exhibited linear response with Nernstian slope of 57.6±0.8 mV per decade within the range of 1.0×10 to 1.0×10 M with limit of detection 6.5×10 M silver ion. Fast and...
متن کاملAll-Solid-State Sodium-Selective Electrode with a Solid Contact of Chitosan/Prussian Blue Nanocomposite
Conventional ion-selective electrodes with a liquid junction have the disadvantage of potential drift. All-solid-state ion-selective electrodes with solid contact in between the metal electrode and the ion-selective membrane offer high capacitance or conductance to enhance potential stability. Solution-casted chitosan/Prussian blue nanocomposite (ChPBN) was employed as the solid contact layer f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Chemistry
سال: 2014
ISSN: 0003-2700,1520-6882
DOI: 10.1021/ac5029209