All-Optical Nonzero-Field Vector Magnetic Sensor for Magnetoencephalography

نویسندگان

چکیده

We present the concept and results of an investigation all-optical vector-magnetic-field sensor scheme developed for biological applications such as nonzero-field magnetoencephalography magnetocardiography. The differs from classical two-beam Bell-Bloom in that detecting laser beam is split into two beams, which are introduced cell orthogonal directions, ratio amplitudes magnetic resonance signals these beams their phase difference measured; strong optical pumping lower hyperfine level ground state ensures line narrowing, detection carried out balanced schemes by measuring beam-polarization rotation. proposed compact, resistant to variations parameters radiation highly sensitive angle deflection field vector---with estimated scalar sensitivity order $16\phantom{\rule{0.2em}{0ex}}{\mathrm{fT}/\mathrm{Hz}}^{1/2}$ $8\ifmmode\times\else\texttimes\fi{}8\ifmmode\times\else\texttimes\fi{}8\phantom{\rule{0.2em}{0ex}}{\mathrm{mm}}^{3}$ cell, angular $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$ rad, or 0.08'', was demonstrated.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the Exterior Magnetic Field and Silent Sources in Magnetoencephalography

Two main results are included in this paper. The first one deals with the leading asymptotic term of the magnetic field outside any conductive medium. In accord with physical reality, it is proved mathematically that the leading approximation is a quadrupole term which means that the conductive brain tissue weakens the intensity of the magnetic field outside the head. The second one concerns th...

متن کامل

YIG Film for Magnetic Field Sensor

Single crystal Y3Fe5O12 (YIG) lm was grown onto (111) oriented gadolinium gallium garnet (GGG) substrate by the liquid phase epitaxy (PLD) technique. The X-ray di raction measurements showed that epitaxial growth of the lm along its (111) axis. The surface characteristic was investigated by atomic force microscopy (AFM) measurement. The magnetic eld sensor consisted of a rectangular shape with ...

متن کامل

Designated magnetic field design for magnetic drug guidance in BNCT

In this paper, a local magnetic field was designed and simulated using a Helmholtz coil along with a ferromagnetic core with an appropriate geometric Structure to concentrate a magnetic flux. This field can be used for magnetic guiding of Boron-borne drugs in BNCT.

متن کامل

All Inkjet - Printed B Field Sensor †

This paper presents the realization and the experimental characterization of a low cost inkjet-printed DC magnetic field sensor. The device consists of a thin flexible cantilever beam operated at its first resonance frequency by the interaction between the target magnetic field and an AC current flowing through a coil printed on the beam. A resistive readout strategy is implemented by a printed...

متن کامل

All-optical magnetic resonance in semiconductors

A scheme is proposed wherein nuclear magnetic resonance (NMR) can be induced and monitored using only optical fields. In analogy to radio-frequency fields used in traditional NMR, circularly polarized light creates electron spins in semiconductors whose hyperfine coupling could tip nuclear moments. Time-resolved Faraday rotation experiments were performed in which the frequency of electron Larm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical review applied

سال: 2023

ISSN: ['2331-7043', '2331-7019']

DOI: https://doi.org/10.1103/physrevapplied.20.024001