Alignment of spinal column after harrington instrumentation surgery of the fractured thoracic and lumbar spine.
نویسندگان
چکیده
منابع مشابه
Intraoperative spinal sonography in thoracic and lumbar fractures: evaluation of Harrington rod instrumentation.
Thirty-seven patients with thoracic and lumbar spine fractures were treated with Harrington rod instrumentation (HRI), and the progress and results of that surgery were monitored with intraoperative spinal sonography (IOSS). Adequate neural tissue decompression and spinal column alignment was achieved in less than one-half (14/31, 45%) of the patients in whom HRI was performed as the first step...
متن کاملEndovascular treatment of thoracic aorta injury after spinal column surgery.
A 61-year-old woman with a history of left dorso-lumbar scoliosis and severe dorso-lumbar kyphosis underwent surgical treatment of a spinal deformity. Surgery was conducted on the patient by performing a dorso-lumbar spinal arthrodesis (T6-L5) by means of the insertion of two longitudinal rods and a number of pedicle-expander screws at different vertebral levels. Following the orthopedic surger...
متن کاملNew Spinal Instrumentation for Thoracic and Lumbar Spine a Preliminary Clinical Report
SUMMARY : The new system described here is a segmental square spinal instru-mentation (termed 3-S) for spinal fusion. It consists of pairs of transverse bars, hooks and longitudinal rods. The hooks are inserted bilaterally to each lateral side of the inferior articular process. The paired hook are compressed by two transverse bars and a nut. Upper and lower hooks were linked by longitudinal rod...
متن کاملContinuous spinal analgesia after extensive lumbar spine surgery.
A 77-year-old male underwent L-1 to S-1 spine decompression and fusion from L-3 to S-1. A 25 G spinal catheter was placed intraoperatively and bupivacaine 1.25 mg/ml, fentanyl 2 microg/ml and morphine 3 microg/ml infused. The patient was pain-free for the duration of the infusion. Continuous spinal analgesia was effective after extensive spinal surgery. The risks of post-dural puncture headache...
متن کاملFrequency of Instrumentation in Lumbar Spinal Stenosis and Lumbar Disc Herniation
Background & Aim: Lumbosacral pain is extremely common as age increases. Spinal instrumentation is sometimes recommended for lumbar canal stenosis and disk herniation surgery. This study aimed at studying the frequency of instrumentation in patients referring to our center. Methods & Materials/Patients: This retrospective cross-sectional study included 1200 patients with low back and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopedics & Traumatology
سال: 1983
ISSN: 1349-4333,0037-1033
DOI: 10.5035/nishiseisai.31.579