AIRFLOW MEASUREMENT TEST DEVICE FOR AIRFLOW SENSORS

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Ultrasonic Airflow Measurement Device for Ducted Air

In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of co...

متن کامل

Airflow Measurement for HVAC Systems – Comparing Technologies

The proper selection of airflow measurement devices can be critical to the performance of today’s state-of-the-art HVAC system. Many of the requirements and limitations of one technology are often mistakenly thought to apply to every other. Not all technologies result in equal performance, even when used under similar conditions. Accuracy and repeatability vary between technologies and are most...

متن کامل

Forced expiration: a test for airflow obstruction in horses.

The purpose of this study was to assess whether our method of inducing forced expiration detects small airway obstruction in horses. Parameters derived from forced expiratory flow-volume (FEFV) curves were compared with lung mechanics data obtained during spontaneous breathing in nine healthy horses, in three after histamine challenge, and in two with chronic obstructive pulmonary disease (COPD...

متن کامل

Masks for influenza patients: measurement of airflow from the mouth.

In case of a new influenza pandemic, provision of masks to coughing patients could be used to slow expansion of the epidemic. To quantitatively assess the efficacy of different masks, we used an ultrasonic anemometer to measure the velocity of airflow from the mouth in coughing. We found that even the cheapest paper masks reduced the air speed to less than 1/10, implicating their effectiveness ...

متن کامل

Testing limits to airflow perturbation device (APD) measurements

BACKGROUND The Airflow Perturbation Device (APD) is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Mechatronica

سال: 2019

ISSN: 2453-7306

DOI: 10.22306/am.v4i4.52