Air-source heat pump performance comparison in different real operational conditions based on advanced exergy and exergoeconomic approach

نویسندگان

چکیده

The use of air-source heat pumps (ASHP) is increasing to meet the energy needs residential buildings, and manufacturers equipment have permanently expanded range work improved efficiency in very adverse outdoor air conditions. However, time a wide different technologies, problem using ASHP, from techno-economic point view, constantly present. Exergetic exergoeconomic cost no longer provide sufficiently reliable information when it necessary reduce investment costs or in-crease energy/exergetic component/system. This paper presents comparison ASHP operational conditions based on an advanced exergy approach. analysis splits destruction for each individual component into avoidable unavoidable part order fully understand processes. stream used calculate variables associated with system component. Irreversibility compressor greatest impact reducing overall exergetic by 46.7% during underfloor heating (UFH) operation 24.53% domestic hot water (DHW) operation. Exergy loss reduces 5.72% UFH 39.74% DHW. High values both operating regimes are present flows 1, 2, 3 4 due high production relatively small levels. general recommendation set operate near-optimal capacities then 5, 11, 13.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump

In residential heat pump systems, the motivation for secondary loop systems is to allow for the use of flammable or toxic refrigerants with lower global warming potentials than the currently employed HFC refrigerants. The addition of radiant panels as integral building components (embedded in concrete at construction or attached to the underside of wood flooring) is becoming more common. Combin...

متن کامل

Assessment of a Real Combined Cycle Power Plant with Supplementary Firing Based on Advanced Exergy/Exergoeconomic Methods

This research performs the advanced exergy and exergoeconomic analyses of a combined cycle power plant (CCPP) located in Zavareh, Iran. The objective of this research is to evaluate the irreversibilities, their related cost rates of each part of the CCPP that can be avoided and the inefficiencies of each part that caused by other components. The advanced exergy and exergoeconomic analyses indic...

متن کامل

Assessment and Deployment of Ground Source Heat Pump for Air Pollution Reduction in Tehran, Iran

The use of renewable energies, especially in metropolises has led to a reduction in environmental pollution and greater access to clean, renewable and sustainable energy. This paper evaluates the effectiveness of a national plan adopted by the Tehran city council for reducing air pollutions. This plan is designed to increase the share of renewable energies in residential buildings. This study a...

متن کامل

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thermal Science

سال: 2021

ISSN: ['0354-9836', '2334-7163']

DOI: https://doi.org/10.2298/tsci200529237v