Addressing the practicalities of anodic stripping voltammetry for heavy metal detection: a tutorial review

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heavy Metal Analysis by Anodic Stripping Voltammetry

Let’s say that you wanted to determine the heavy metal identities and concentrations in sediment and suspended solid samples obtained from present day Lake Nakuru. What technique would you use for this determination? You could use Atomic Absorption Spectroscopy (AAS) as was done in the article (Nelson 1998), but another technique, which is particularly good at detecting metals at the ppb level ...

متن کامل

Detection of heavy metal ions in water by high-resolution surface plasmon resonance spectroscopy combined with anodic stripping voltammetry.

High-resolution differential surface plasmon resonance (SPR) with anodic stripping voltammetry (ASV) capability has been demonstrated for detecting heavy metal ions in water. Metal ions are electroplated onto the gold SPR sensing surface and are quantitatively detected by stripping voltammetry. Both the SPR angular shift and electrochemical current signal are recorded to identify the type and a...

متن کامل

Cloud Point Extraction for Electroanalysis: Anodic Stripping Voltammetry of Cadmium.

Cloud point extraction (CPE) is a well-established technique for the preconcentration of hydrophobic species from water without the use of organic solvents. Subsequent analysis is then typically performed via atomic absorption spectroscopy (AAS), UV-vis spectroscopy, or high performance liquid chromatography (HPLC). However, the suitability of CPE for electroanalytical methods such as stripping...

متن کامل

Rapid micromethod for blood lead analysis by anodic stripping voltammetry.

We describe a rapid microscale procedure for blood lead determination by anodic stripping voltammetry. Results correlate well with those obtained by atomic absorption spectroscopy. The procedure involves use of a metal-exchange reagent, which rapidly releases bound lead from its macromolecular binding sites, thus eliminating a long and cumbersome perchloric acid digestion procedure. Reproducibi...

متن کامل

Disposable Copper-Based Electrochemical Sensor for Anodic Stripping Voltammetry

In this work, we report the first copper-based point-of-care sensor for electrochemical measurements demonstrated by zinc determination in blood serum. Heavy metals require careful monitoring, yet current methods are too complex for a point-of-care system. Electrochemistry offers a simple approach to metal detection on the microscale, but traditional carbon, gold (Au), or platinum (Pt) electrod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Analyst

سال: 2019

ISSN: 0003-2654,1364-5528

DOI: 10.1039/c9an01437c