Freehand 3D Ultrasound Calibration: A Review
Freehand three-dimensional ultrasound is a technique for acquiring ultrasonic data of a 3D volume by recording the trajectory of the ultrasound probe using a position sensor. In planning and registration, a freehand ultrasound systems is used to track a two-dimensional probe. Probe calibration is necessary to find the rigid body transformation from the coordinate system of the B-scan to that of...
متن کاملAutomatic Calibration of 3D Ultrasound Probes
Navigation systems based on intra-operative ultrasound have been introduced for different surgical procedures and interventions. The accuracy of the ultrasound probe calibration is a main contribution to the overall accuracy of the navigation system. Different calibration methods based on phantoms have been introduced. The challenge of the calibration procedure is to identify the phantom struct...
متن کاملCalibration of Swept-Volume 3D Ultrasound
We present two different methods for calibrating 3D swept-volume ultrasound as a prerequisite for an ultrasound based intraoperative navigation system. Different solutions of the calibration problem for 2D ultrasound exist, but no approach has been published so far that takes advantage of 3D swept-volume ultrasound. In contrast to 3D freehand ultrasound no compounding has to be performed. Inste...
متن کاملA Rapid Calibration Method for Registration and 3D Tracking of Ultrasound Images Using Spatial Localizer
Conventional freehand 3D ultrasound (US) is a complex process, involving calibration, scanning, processing, volume reconstruction, and visualization. Prior to calibration, a position sensor is attached to the probe for tagging each image with its position and orientation in space; then calibration process is performed to determine the spatial transformation of the scan plan with respect to the ...
متن کاملReal-time freehand 3D ultrasound calibration.
Z-fiducial phantoms allow three-dimensional ultrasound probe calibration with a single B-scan. One of the main difficulties in using this phantom is the need for reliable segmentation of the wires in the ultrasound images, which necessitates manual intervention. In this article, we have shown how we can solve this problem by mounting a thin rubber membrane on top of the phantom. The membrane is...