Adaptive Single-Pole Auto-Reclosing Scheme Based on Secondary Arc Voltage Harmonic Signatures

نویسندگان

چکیده

This paper presents an advanced adaptive single-pole auto-reclosing (ASPAR) scheme based on harmonic characteristics of the secondary arc voltage. For analysis harmonics, short-time Fourier transform (STFT), which is a universal signal processing tool for transforming from time domain to frequency domain, utilized. STFT applied extract abnormal signature voltage waveform faulted phase when transient or permanent fault occurs power transmission line. The proposed uses total distortion (THD) factor determine type variation and harmonics. Harmonic components in order odd/even are also utilized detect extinction guide reclosing operation. Based these factors, two coordinated algorithms reduce unnecessary dead conventional methods enable optimal operation event ground fault. ASPAR implemented using electromagnetic program (EMTP), various simulations conducted actual 345 765 kV Korean study systems.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One Terminal Digital Algorithm for Adaptive Single Pole Auto-Reclosing Based on Zero Sequence Voltage

This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point. If the fault is recognised asan arcing one, then the third harmonic of the zero...

متن کامل

Implementation of Fast Adaptive Single-Phase Reclosing Based on Measurement of Harmonic Content in the Real-Time Digital Simulator (RTDS)

This paper presents the implementation of a fast adaptive single-phase reclosing scheme based on the measurement of voltage harmonic content. The main objective of this scheme is to ensure the application of single-phase reclosing after the transient fault extinction or perform automatic blocking maneuver and three-phase tripping for permanent faults. The transmission system represented was bas...

متن کامل

Reclosing Evaluation Using Simplified Arc Model

The interaction between a fault arc and power system has a big influence on the successful reclosing of a faulted system and hence evaluation of this interaction is very important. This paper mainly focuses on a proposed technique of simplified arc model for evaluation of single phase reclosing scheme for extra high voltage transmission system. Both primary and secondary arcs behavior have been...

متن کامل

Signtiming Scheme based on Aggregate Signatures

The aim of timestamping systems is to provide a proof-of-existence of a digital document at a given time. By timestamping a digital document after it has been signed by concerned parties, we know when the document was signed. Timestamping services also provide the non-repudiation and long term properties for digital signatures. Combining both digital signature and provable timestamping guarante...

متن کامل

Fault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests

In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14051311