Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension® analyzer

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension analyzer.

At present no method for glycohemoglobin (%HbA1c) is automated on a main-line analyzer to allow joint measurement with other indicators of diabetic control such as glucose and cholesterol. We describe an adaptation of a latex-enhanced competitive immunoassay for quantifying %HbA1c to the Dade International Dimension analyzer. After a manual hemolysis step, HbA1c and total hemoglobin (Hb) are de...

متن کامل

Enhanced-latex-agglutination assay for C-reactive protein in serum, with use of a centrifugal analyzer.

This is an improved assay of C-reactive protein in serum, for use with the Baker "Encore" centrifugal analyzer. Features of this assay include: 250-specimen throughput per hour, within-batch CV 2.2%, between-batch CV 2.7%, no antigen-excess problems up to 1000 mg/L, negligible interference from rheumatoid factor, and good correlation (r = 0.99) with radial immunodiffusion. The method is inexpen...

متن کامل

Simple precipitation-based method for the screening of type III hyperlipoproteinemia.

heterozygous, double-heterozygous and homozygous subjects, as established by 13 methods. Clin Chim Acta 1994;231:161–71. 10. Martina WV, Martijn EG, van der Molen M, Schermer JG, Muskiet FAJ. b-N-Terminal glycohemoglobin in subjects with common hemoglobinopathies: relation with fructosamine and mean erythrocyte age. Clin Chem 1993;39:2259–65. 11. Holownia P, Bishop E, Newman DJ, John GW, Price ...

متن کامل

Evaluation of a no-pretreatment cyclosporin A assay on the Dade Behring dimension RxL clinical chemistry analyzer.

BACKGROUND Monitoring whole-blood concentrations of cyclosporin A (CsA) is common practice in the management of solid organ and bone marrow transplant recipients. In a multicenter study we evaluated a new, direct (no pretreatment) CsA assay on the Dade Behring Dimension RxL system and compared results with those from the Abbott TDx CsA immunoassay and a HPLC method. METHODS Whole-blood sample...

متن کامل

New enzymatic assay for glycohemoglobin.

BACKGROUND Previous methods to measure glycohemoglobin (GHb) have been time-consuming or imprecise; we therefore developed a new enzymatic assay for GHb. METHODS Blood cells were first hemolyzed, and hemoglobin was digested with protease to yield fructosyl amino acid. Fructosyl amino acid oxidase acts on the fructosyl amino acid and generates hydrogen peroxide, which reacts with chromogens in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 1997

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/43.1.76