Adaptation of a cold vapour mercury analyser to flow injection analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of a cold vapour mercury analyser to flow injection analysis

Minor modifications to a Coleman MAS-50A Mercury Analyser System allowed the determination of mercury by flow injection analysis. Using sample volumes of 600 mul it was possible to analyse up to 120 samples per hour, with a detection limit of 0.2 mug. l(-1) (120 pg) of mercury. The authors also report on a simple digestion procedure which replaces the time- and reagent-consuming EPA procedure, ...

متن کامل

Automated cold vapour flow-injection analysis of mercury at high concentrations

Continuous-flow cold vapour- atomic fluorescence spectrometry is shown to be an extremely sensitive technique for the determination of mercury with detection limits typically below 0.01 mug l(-1). Linear calibration ranges were found to be at least four orders of magnitude (i.e. up to 0.1 mg l(-1)). Samples with concentrations exceeding the linear range are susceptible to self-absorption, and m...

متن کامل

Operator-free flow injection analyser

A flow injection analyser has been constructed to allow an operator-free determination of up to 40 samples. Besides the usual FIA apparatus, the analyser includes a home-made sample introduction device made with three electromechanical three-way valves and an auto-sampler from Technicon which has been adapted to be commanded by an external digital signal. The analyser is controlled by a single ...

متن کامل

Determination of total mercury in biological tissues by flow injection cold vapour generation atomic absorption spectrometry following tetramethylammonium hydroxide digestion.

A simple, rapid and reliable method was developed for the determination of total mercury in biological samples. Samples were solubilized using tetramethylammonium hydroxide (TMAH). The organically bound mercury was cleaved and converted to inorganic mercury by on-line addition of KMnO4. The decomposed mercury together with inorganic mercury originally present in samples was determined by flow i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Automatic Chemistry

سال: 1988

ISSN: 0142-0453

DOI: 10.1155/s1463924688000409