Adaptable Xerogel-Layered Amperometric Biosensor Platforms on Wire Electrodes for Clinically Relevant Measurements

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...

متن کامل

Amperometric biosensor for ascorbic acid

A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L phosphate buffer, pH 5.8 containing 0.5 mol L NaCl. After the dialysis versus phosphate buffer 0.05 mol L pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O 2 ...

متن کامل

Gold nanoparticles-enhanced amperometric tyrosinase biosensor based on three-dimensional sol-gel film-modified gold electrodes.

An amperometric biosensor for the determination of catechol was developed by immobilizing tyrosinase (tyr) on gold nanoparticles (AuNPs) and a (3-mercaptopropyl)-trimethoxysilane (MPTS) sol-gel three-dimensional network film-modified gold electrode. The AuNPs self-assembled in a sol-gel network provided an excellent microenvironment for an enzymatic reaction between tyrosinase and the substrate...

متن کامل

Amperometric Oxygen Electrodes

Although the Winkler method is very precise when performed with strict control of pH and iodine concentration, it is still susceptible to errors. For example, ions such as Fe2+ and SO3-, suspended solids, and some organics can produce gross inaccuracies. There have been numerous modifications of the method over the years to compensate for its shortcomings (2). Besides the errors inherent in the...

متن کامل

Amperometric Oxygen Electrodes

Although the Winkler method is very precise when performed with strict control of pH and iodine concentration, it is still susceptible to errors. For example, ions such as Fe2+ and SO3-, suspended solids, and some organics can produce gross inaccuracies. There have been numerous modifications of the method over the years to compensate for its shortcomings (2). Besides the errors inherent in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2019

ISSN: 1424-8220

DOI: 10.3390/s19112584