Acute shock efficacy of the subcutaneous implantable cardioverter‐defibrillator according to the implantation technique

نویسندگان

چکیده

BACKGROUND The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a (SC) pocket. An intermuscular (IM) 2-incision has been recently adopted. AIMS We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the technique. METHODS analyzed consecutive patients who underwent DE testing at 53 Italian centers. Regression analysis was used determine association between DFT RESULTS A total 805 were enrolled. Four groups assessed: IM + 2 (n = 546), SC + 2 (n = 133), SC + 3 (n = 111), IM + 3 (n = 15). ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed trend towards lower body mass index (25.1 vs. 26.5; p = .12), less frequently on antiarrhythmic drugs (13% 26%; p = .06) more commonly (85% 70%; p = .04). IM + 2-incision lowest failure rate (2.2%) shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, associated incidence (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock IM than SC approach (66 70 Ohm p = .002) 3-incision (67 72 Ohm; p = .006). CONCLUSIONS In large population patients, we observed high success rate. provides higher likelihood successful defibrillation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantation of the Subcutaneous Implantable Cardioverter-Defibrillator

The subcutaneous implantable cardioverter-defibrillator (S-ICD) was introduced to reduce acute transvenous leadrelated complications, such as pneumothorax, endocarditis, cardiac perforation, and lead dislodgements, as well as the complications related to chronic indwelling leads, such as lead failure, venous obstruction, and bacteremia. The standard implantation technique of the S-ICD involves ...

متن کامل

surveying the relevance of proportions to the content of quran verses

چکیده : قرآن چشمه سار زلال هدایتی است که از سوی خداوند حکیم نازل شده تا بشر را به سر منزل کمال برساند. و در این راستا از شیوه های گوناگون بیانی خطابی و بلاغی استفاده کرده تا با فطرت زیبا طلب انسان درآمیزد و اورا مقهور خویش ساخته، به سوی کمالات سوق دهد.ازجمله جنبه های بارز اعجاز بیانی قرآن وجود فواصل در پایان آیات است که کار برد سجع و قافیه در کلام بشر شبیه آن است. برخی ازعلمای سلف تفاوت هایی ب...

15 صفحه اول

from linguistics to literature: a linguistic approach to the study of linguistic deviations in the turkish divan of shahriar

chapter i provides an overview of structural linguistics and touches upon the saussurean dichotomies with the final goal of exploring their relevance to the stylistic studies of literature. to provide evidence for the singificance of the study, chapter ii deals with the controversial issue of linguistics and literature, and presents opposing views which, at the same time, have been central to t...

15 صفحه اول

extensions of some polynomial inequalities to the polar derivative

توسیع تعدادی از نامساوی های چند جمله ای در مشتق قطبی

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Electrophysiology

سال: 2021

ISSN: ['1540-8167', '1045-3873']

DOI: https://doi.org/10.1111/jce.15081