Acute dysfunction of Starr-Edwards mitral prostheses

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute dysfunction of Starr-Edwards mitral prostheses.

Four cases of acute dysfunction of Starr-Edwards mitral prostheses are recorded. The patients presented with sudden dyspnoea 4 to 18 months after apparently successful mitral valve replacement. The prosthetic valve dysfunction was caused by thrombus on the bare metal cage of the prosthesis. No warning thromboembolic phenomena had been recorded. Urgent replacement of the valve resulted in the su...

متن کامل

Role of echocardiography and phonocardiography in diagnosis of mitral paraprosthetic regurgitation with Starr-Edwards prostheses.

Twenty-three patients who were symptomatic after mitral valve replacement, and in whom mitral paraprosthetic regurgitation was a possible cause of deterioration, were investigated by cardiac catheterization, phonocardiography, and echocardiography. Severe paraprosthetic regurgitation was present in ii patients and slight regurgitation in 2 patients. Two patients had aortic regurgitation which w...

متن کامل

Diastolic murmurs in the presence of Starr-Edwards mitral prosthesis.

Diastolic murmurs associated with the Starr-Edwards mitral prosthesis have not been described previously. In this report, five patients with mitral prostheses are described in whom apical mid-diastolic and presystolic murmurs resulted from two different causes. Three patients had clots obstructing the prosthetic orifice. The other two had normally functioning protheses and moderately severe aor...

متن کامل

Thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral.

The thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral followed for an average of 14 months in 155 patients are reviewed. There was a high incidence of early fatal and disabling thrombo-embolus in patients 'having mitral valve replacement. Late emboli were more common after aortic valve replacement. Anticoagulant control was unsatisfa...

متن کامل

Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thorax

سال: 1971

ISSN: 0040-6376

DOI: 10.1136/thx.26.2.163