Active wavelength selection for mixture identification with tunable mid-infrared detectors.

This article presents a wavelength selection framework for mixture identification problems. In contrast with multivariate calibration, where the mixture constituents are known and the goal is to estimate their concentration, in mixture identification the goal is to determine which of a large number of chemicals is present. Due to the combinatorial nature of this problem, traditional wavelength ...

متن کامل

Active wavelength selection for mixture analysis with tunable infrared detectors

This article presents an active wavelength selection algorithm for multicomponent analysis with tunable infrared sensors. Traditional techniques for wavelength selection operate off-line; as a result, the resulting feature subset is fixed and only optimal for the specific mixtures and noise levels in the training set. To address this limitation, the proposed algorithm interleaves the wavelength...

متن کامل

Mid-Infrared Tunable Resonant Cavity Enhanced Detectors

Mid-infrared detectors that are sensitive only in a tunable narrow spectral band are presented. They are based on the Resonant Cavity Enhanced Detector (RCED) principle and employing a thin active region using IV-VI narrow gap semiconductor layers. A Fabry-Pérot cavity is formed by two mirrors. The active layer is grown onto one mirror, while the second mirror can be displaced. This changes the...

متن کامل

Data compressive paradigm for multispectral sensing using tunable DWELL mid-infrared detectors.

While quantum dots-in-a-well (DWELL) infrared photodetectors have the feature that their spectral responses can be shifted continuously by varying the applied bias, the width of the spectral response at any applied bias is not sufficiently narrow for use in multispectral sensing without the aid of spectral filters. To achieve higher spectral resolutions without using physical spectral filters, ...

متن کامل

Chaotic light at mid-infrared wavelength

The onset of nonlinear dynamics and chaos is evidenced in a mid-infrared distributed feedback quantum cascade laser both in the temporal and frequency domains. As opposed to the commonly observed route to chaos in semiconductor lasers, which involves undamping of the laser relaxation oscillations, quantum cascade lasers first exhibit regular self-pulsation at the external cavity frequency befor...