Active Vibration Control by Maximum Power Absorption.
نویسندگان
چکیده
منابع مشابه
Piezoelectric Power Requirements for Active Vibration Control
This paper presents a method for predicting the power consumption of piezoelectric actuators utilized for active vibration control. Analytical developments and experimental tests show that the maximum power required to control a structure using surface-bonded piezoelectric actuators is independent of the dynamics between the piezoelectric actuator and the host structure. The results demonstrate...
متن کاملActive vibration control of smart building frames by feedback controllers
In this paper the active vibration control of a four-story shear frame instrumented with piezoelectric actuators is presented. The piezoelectric actuators are hosted on the columns in two manners and the produced controlling forces by actuators are considered in the equation of motion. The smart structure modeling and control design is carried out using MATLAB software in state space form. Subs...
متن کاملactive vibration control of smart building frames by feedback controllers
in this paper the active vibration control of a four-story shear frame instrumented with piezoelectric actuators is presented. the piezoelectric actuators are hosted on the columns in two manners and the produced controlling forces by actuators are considered in the equation of motion. the smart structure modeling and control design is carried out using matlab software in state space form. subs...
متن کاملActive Vibration Control
In order to motivate the use of active vibration control, consider the future interferometric missions planned by NASA or ESA (one such a mission, called ”Terrestrial Planet Finder” aims at detecting earth-sized planets outside the solar system; other missions include the mapping of the sky with an accuracy one order better than that achieved by Hypparcos). The purpose is to use a number of sma...
متن کاملVibration control of an automotive engine using active mounts
In this research, vibration control of national engine (EF7) using active mounts is studied for two different mounting layouts. The first layout is based on the current engine mounting of national engine (system of three passive mounts), but the hydraulic mount is substituted by an active mount. The other mounting layout contains 4 mounts, 2 of which are active ones and the others are passive m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
سال: 1998
ISSN: 0387-5024,1884-8354
DOI: 10.1299/kikaic.64.444